Human Indoleamine 2,3-dioxygenase/IDO Antibody (700838)
R&D Systems | Catalog # MAB6030
Scientific images may be resized, cropped, or adjusted for brightness or contrast for presentation purposes. These updates are limited to presentation and do not affect the underlying scientific interpretation of the data. Where available, additional source data may be provided upon request.
Key Product Details
Validated by
Species Reactivity
Validated:
Cited:
Applications
Validated:
Cited:
Label
Antibody Source
Product Specifications
Immunogen
Ala2-Gly403
Accession # P14902
Specificity
Clonality
Host
Isotype
Scientific Data Images for Human Indoleamine 2,3-dioxygenase/IDO Antibody (700838)
Indoleamine 2,3-dioxygenase/IDO in A431 Human Cell Line.
Indoleamine 2,3-dioxygenase/IDO was detected in immersion fixed A431 human epithelial carcinoma cells stimulated with 0.5 ng/mL of Recombinant Human IFN-gamma (Catalog # 285-IF) using Mouse Anti-Human Indoleamine 2,3-dioxygenase/IDO Monoclonal Antibody (Catalog # MAB6030) at 10 µg/mL for 3 hours at room temperature. Cells were stained using the NorthernLights™ 557-conjugated Anti-Mouse IgG Secondary Antibody (red; Catalog # NL007) and counter-stained with DAPI (blue). Specific staining was localized to cytoplasm. View our protocol for Fluorescent ICC Staining of Cells on Coverslips.Detection of Indoleamine 2,3‑dioxygenase/IDO in Human MDSCs by Flow Cytometry.
Human PBMC-derived myeloid-derived suppressor cells (MDSCs) treated with 10 ng/mL Recombinant Human IL-6 (Catalog # 206-IL) and 10 ng/mL Recombinant Human GM-CSF (Catalog # 215-GM) for 7 days were stained with Mouse Anti-Human Siglec-3/CD33 APC-conjugated Monoclonal Antibody (Catalog # FAB1137A) and either (A) Mouse Anti-Human Indoleamine 2,3-dioxygenase/IDO Monoclonal Antibody (Catalog # MAB6030) or (B) Mouse IgG1Isotype Control (Catalog # MAB002) followed by Phycoerythrin-conjugated Anti-Mouse IgG Secondary Antibody (Catalog # F0102B). To facilitate intracellular staining, cells were fixed with paraformaldehyde and permeabilized with saponin. View our protocol for Staining Intracellular Molecules.Detection of Indoleamine 2,3‑dioxygenase/IDO in Human Monocytes by Flow Cytometry.
Human Monocytes were selected from PBMC using MagCellect Human CD14+ Cell Isolation Kit (Catalog # MAGH105) and cultured overnight with (A) 50 ng/mL Recombinant Human MCSF (Catalog # 216-MC), 50 ng/mL Recombinant Human IFNg (Catalog # 285-IF) and 50 ng/mL LPS, or (B) Recombinant Human MCSF alone. Cells were stained with Mouse Anti-Human Indoleamine 2,3-dioxygenase/IDO Monoclonal Antibody (Catalog # MAB6030) followed by APC-conjugated Anti-Mouse IgG Secondary Antibody (Catalog # F0101B) and Mouse Anti-Human CD14 PE-conjugated Monoclonal Antibody (Catalog # FAB3832P). Quadrant markers were set based on Mouse IgG1 Isotype Control (Catalog # MAB002). To facilitate intracellular staining, cells were fixed with 1% paraformaldehyde and permeabilized with saponin. View our protocol for Staining Intracellular Molecules.Applications for Human Indoleamine 2,3-dioxygenase/IDO Antibody (700838)
CyTOF-ready
Immunocytochemistry
Sample: Immersion fixed A431 human epithelial carcinoma cell line
Intracellular Staining by Flow Cytometry
Sample: Human myeloid-derived suppressor cells (MDSCs) treated with Recombinant Human IL‑6 (Catalog # 206-IL) and Recombinant Human GM‑CSF (Catalog # 215-GM), and Human Monocytes selected from PBMC using MagCellect Human CD14+ Cell Isolation Kit (Catalog # MAGH105) and cultured with Recombinant Human MCSF (Catalog # 216-MC), Recombinant Human IFNg (Catalog # 285-IF) and LPS, were fixed with paraformaldehyde and permeabilized with saponin
Flow Cytometry Panel Builder
Bio-Techne Knows Flow Cytometry
Save time and reduce costly mistakes by quickly finding compatible reagents using the Panel Builder Tool.
Advanced Features
- Spectra Viewer - Custom analysis of spectra from multiple fluorochromes
- Spillover Popups - Visualize the spectra of individual fluorochromes
- Antigen Density Selector - Match fluorochrome brightness with antigen density
Formulation, Preparation, and Storage
Purification
Reconstitution
Sterile PBS to a final concentration of 0.5 mg/mL. For liquid material, refer to CoA for concentration.
Formulation
Shipping
Stability & Storage
- 12 months from date of receipt, -20 to -70 °C as supplied.
- 1 month, 2 to 8 °C under sterile conditions after reconstitution.
- 6 months, -20 to -70 °C under sterile conditions after reconstitution.
Calculators
Background: Indoleamine 2,3-dioxygenase/IDO
References
- Lewis-Ballester, A. et al. (2009) Proc. Natl. Acad. Sci. USA. 106:17371.
- Costantino, G. (2009) Expert Opin. Ther. Targets 13:247.
- Xu, H. et al. (2008) Immunol. Lett. 121:1.
- Lob, S. et al. (2009) Nat. Rev. Cancer 9:445.
- Curti, A. et al. (2009) Blood 113:2394.
Alternate Names
Gene Symbol
UniProt
Additional Indoleamine 2,3-dioxygenase/IDO Products
Product Documents for Human Indoleamine 2,3-dioxygenase/IDO Antibody (700838)
Certificate of Analysis
To download a Certificate of Analysis, please enter a lot or batch number in the search box below.
Note: Certificate of Analysis not available for kit components.
Product Specific Notices for Human Indoleamine 2,3-dioxygenase/IDO Antibody (700838)
For research use only
Related Research Areas
Citations for Human Indoleamine 2,3-dioxygenase/IDO Antibody (700838)
Customer Reviews for Human Indoleamine 2,3-dioxygenase/IDO Antibody (700838)
There are currently no reviews for this product. Be the first to review Human Indoleamine 2,3-dioxygenase/IDO Antibody (700838) and earn rewards!
Have you used Human Indoleamine 2,3-dioxygenase/IDO Antibody (700838)?
Submit a review and receive an Amazon gift card!
$25/€18/£15/$25CAN/¥2500 for a review with an image
$10/€7/£6/$10CAN/¥1110 for a review without an image
Submit a review
Protocols
Find general support by application which include: protocols, troubleshooting, illustrated assays, videos and webinars.
- 7-Amino Actinomycin D (7-AAD) Cell Viability Flow Cytometry Protocol
- Appropriate Fixation of IHC/ICC Samples
- Cellular Response to Hypoxia Protocols
- ClariTSA™ Fluorophore Kits
- Detection & Visualization of Antibody Binding
- Extracellular Membrane Flow Cytometry Protocol
- Flow Cytometry Protocol for Cell Surface Markers
- Flow Cytometry Protocol for Staining Membrane Associated Proteins
- Flow Cytometry Staining Protocols
- Flow Cytometry Troubleshooting Guide
- ICC Cell Smear Protocol for Suspension Cells
- ICC Immunocytochemistry Protocol Videos
- ICC for Adherent Cells
- Immunocytochemistry (ICC) Protocol
- Immunocytochemistry Troubleshooting
- Immunofluorescence of Organoids Embedded in Cultrex Basement Membrane Extract
- Immunohistochemistry (IHC) and Immunocytochemistry (ICC) Protocols
- Intracellular Flow Cytometry Protocol Using Alcohol (Methanol)
- Intracellular Flow Cytometry Protocol Using Detergents
- Intracellular Nuclear Staining Flow Cytometry Protocol Using Detergents
- Intracellular Staining Flow Cytometry Protocol Using Alcohol Permeabilization
- Intracellular Staining Flow Cytometry Protocol Using Detergents to Permeabilize Cells
- Preparing Samples for IHC/ICC Experiments
- Preventing Non-Specific Staining (Non-Specific Binding)
- Primary Antibody Selection & Optimization
- Propidium Iodide Cell Viability Flow Cytometry Protocol
- Protocol for Liperfluo
- Protocol for VisUCyte™ HRP Polymer Detection Reagent
- Protocol for the Characterization of Human Th22 Cells
- Protocol for the Characterization of Human Th9 Cells
- Protocol for the Fluorescent ICC Staining of Cell Smears - Graphic
- Protocol for the Fluorescent ICC Staining of Cultured Cells on Coverslips - Graphic
- Protocol for the Preparation and Fluorescent ICC Staining of Cells on Coverslips
- Protocol for the Preparation and Fluorescent ICC Staining of Non-adherent Cells
- Protocol for the Preparation and Fluorescent ICC Staining of Stem Cells on Coverslips
- Protocol for the Preparation of a Cell Smear for Non-adherent Cell ICC - Graphic
- Protocol: Annexin V and PI Staining by Flow Cytometry
- Protocol: Annexin V and PI Staining for Apoptosis by Flow Cytometry
- TUNEL and Active Caspase-3 Detection by IHC/ICC Protocol
- The Importance of IHC/ICC Controls
- Troubleshooting Guide: Fluorokine Flow Cytometry Kits
- View all Protocols, Troubleshooting, Illustrated assays and Webinars