Siglecs are sialic acid specific I-type lectins that belong to the immunoglobulin superfamily. Structurally, they are transmembrane proteins with an N-terminal Ig-like V‑set domain followed by varying numbers of Ig-like C2-set domains (1, 2). Human Siglec-1, also known as sialoadhesin and CD169, is a 175‑185 kDa glycoprotein. It contains a 1622 amino acid (aa) extracellular domain (ECD) with one Ig-like V‑set domain and 16 Ig-like C2-set domains, a 21 aa transmembrane segment, and a 44 aa cytoplasmic domain (3). Within the ECD, human Siglec-1 shares approximately 70% aa sequence identity with mouse and rat Siglec-1. Alternate splicing generates a potentially soluble form of the ECD, and a second isoform with a substituted cytoplasmic domain. Siglec-1 expression is restricted to lymph node and splenic macrophages, plus some tissue macrophages (3). The adhesive function of Siglec-1 is supported by the N-terminal Ig-like domain which shows a selectivity for alpha 2,3‑linked sialic acid residues (3‑5). Siglec-1 binds a number of sialylated molecules including the mannose receptor, MGL1, MUC1, PSGL-1, and different glycoforms of CD43 (6‑9). Its binding capacity can be masked by endogenous sialylated molecules (10, 11). The sialylated and sulfated N-linked carbohydrates that modify Siglec-1 itself are required for ligand binding (6, 7). Siglec-1 is expressed on dendritic cells following rhinovirus exposure, and these DC promote T cell anergy (12). It is also induced on circulating monocytes during systemic sclerosis and HIV-1 infection (13‑15). Siglec-1 can trap HIV-1 particles for trans infection of permissive cells (14).
Human Siglec‑1/CD169 Alexa Fluor™ Plus 680‑conjugated Antibody
R&D Systems | Catalog # AF5197AFP680
Key Product Details
Species Reactivity
Applications
Label
Antibody Source
Product Specifications
Specificity
Clonality
Host
Isotype
Applications for Human Siglec‑1/CD169 Alexa Fluor™ Plus 680‑conjugated Antibody
Western Blot
Neutralization
Formulation, Preparation, and Storage
Formulation
Shipping
Stability & Storage
Background: Siglec-1/CD169
References
- Varki, A. and T. Angata (2006) Glycobiology 16:1R.
- Crocker, P.R. et al. (2007) Nat. Rev. Immunol. 7:255.
- Hartnell, A. et al. (2001) Blood 97:288.
- Nath, D. et al. (1995) J. Biol. Chem. 270:26184.
- Crocker, P.R. et al. (1991) EMBO J. 10:1661.
- Martinez-Pomares, L. et al. (1999) J. Biol. Chem. 274:35211.
- Kumamoto, Y. et al. (2004) J. Biol. Chem. 279:49274.
- Nath, D. et al. (1999) Immunology 98:213.
- van den Berg, T.K. et al. (2001) J. Immunol. 166:3637.
- Nakamura, K. et al. (2002) Glycobiology 12:209.
- Barnes, Y.C. et al. (1999) Blood 93:1245.
- Kirchberger, S. et al. (2005) J. Immunol. 175:1145.
- York, M.R. et al. (2007) Arthritis Rheum. 56:1010.
- Rempel, H. et al. (2008) PloS ONE 3:e1967.
- van der Kuyl, A.C. et al. (2007) Plos ONE 2:e257.
Long Name
Alternate Names
Gene Symbol
UniProt
Additional Siglec-1/CD169 Products
Product Documents for Human Siglec‑1/CD169 Alexa Fluor™ Plus 680‑conjugated Antibody
Certificate of Analysis
To download a Certificate of Analysis, please enter a lot or batch number in the search box below.
Note: Certificate of Analysis not available for kit components.
Product Specific Notices for Human Siglec‑1/CD169 Alexa Fluor™ Plus 680‑conjugated Antibody
This product is provided under an intellectual property license from Life Technologies Corporation. The transfer of this product is conditioned on the buyer using the purchased product solely in research conducted by the buyer, excluding contract research or any fee for service research, and the buyer must not (1) use this product or its components for (a) diagnostic, therapeutic or prophylactic purposes; (b) testing, analysis or screening services, or information in return for compensation on a per-test basis; or (c) manufacturing or quality assurance or quality control, and/or (2) sell or transfer this product or its components for resale, whether or not resold for use in research. For information on purchasing a license to this product for purposes other than as described above, contact Life Technologies Corporation, 5781 Van Allen Way, Carlsbad, CA 92008 USA or outlicensing@thermofisher.com.
For research use only
Related Research Areas
Customer Reviews
There are currently no reviews for this product. Be the first to review Human Siglec‑1/CD169 Alexa Fluor™ Plus 680‑conjugated Antibody and earn rewards!
Have you used Human Siglec‑1/CD169 Alexa Fluor™ Plus 680‑conjugated Antibody?
Submit a review and receive an Amazon gift card!
$25/€18/£15/$25CAN/¥2500 Yen for a review with an image
$10/€7/£6/$10CAN/¥1110 Yen for a review without an image
Submit a review
Protocols
Find general support by application which include: protocols, troubleshooting, illustrated assays, videos and webinars.
- Cellular Response to Hypoxia Protocols
- R&D Systems Quality Control Western Blot Protocol
- Troubleshooting Guide: Western Blot Figures
- Western Blot Conditions
- Western Blot Protocol
- Western Blot Protocol for Cell Lysates
- Western Blot Troubleshooting
- Western Blot Troubleshooting Guide
- View all Protocols, Troubleshooting, Illustrated assays and Webinars