Simple Plex AAV6 Cartridge

Catalog #: SPCKB-OT-007971 Datasheet / COA / SDS
Simple Plex AAV6 assay kit for use on Ella instrument. Contains cartridge, sample diluent SD19, and wash buffer
Catalog # Availability Size / Price Qty
SPCKB-OT-007971
ST01B-OT-007971
AAV6 Simple Plex Assay Standard Curve
3 Images
Product Details
FAQs
Reviews

Simple Plex AAV6 Cartridge Summary

Cross-reactivity
< 0.5% cross-reactivity observed with available related molecules.< 50% cross-species reactivity observed with species tested.
Interference
No significant interference observed with available related molecules.

*The Sample Volume represented is based on the amount of sample incorporated into the reaction after taking into account the assay’s minimum required dilution for a given matrix. Serial dilution may be necessary to achieve some of the final sample volumes represented.

Product Summary

Simple Plex assay for the detection of Adeno-Associated Virus type 6 (AAV6) intact capsids in bioprocess samples. 

Recovery

Recovery was not necessary as AAV2 shows natural linearity data from a neat sample to a 1:16 dilution.

Linearity

Samples containing and/or spiked with high concentrations of AAV6 were serially diluted with Sample Diluent to produce samples within the dynamic range of the assay.
AAV6 Simple Plex Assay Linearity

Scientific Data

AAV6 Simple Plex Assay Standard Curve

Product Datasheets

You must select a language.

x

Preparation and Storage

Storage
Store the unopened product at 2 - 8 °C. Do not use past expiration date.

FAQs

  1. Do the AAV assays recognize fully-assembled capsids?

    • Yes, these assays detect fully-assembled capsids. Non-assembled protein or partially assembled capsids will not be detected.

  2. Do the AAV assays recognize both natural and recombinant AAV?

    • Yes, the AAV assays detect both natural and recombinant AAV. 

  3. Does the AAV6 assay recognize other AAV serotypes?

    • This assay recognizes intact AAV6 capsids. The AAV6 antibody (ADK1α) used in this assay cross-reacts with AAV1 and AAV12.

  4. Do the Simple Plex AAV assays distinguish between full and empty capsids?

    • No, the AAV assays do not distinguish between full and empty capsids. Complementary methods are required to distinguish full and empty capsids.

  5. What diluent is provided with the AAV assays?

    • The AAV assays are supplied with SD19 concentrate. The concentrate should be diluted 1:5 in deionized or dilstilled water prior to use. 

  6. What is the minimum required dilution (MRD) for bio-process samples?

    • All samples require a minimum 2-fold dilution for use in Simple Plex assays, but further dilution may be needed for optimal performace. An appropriate dilution factor for each process matrix should be determined experimentally by assessment of sample linearity and spike recovery. 

View all Simple Plex Assays FAQs

Reviews for Simple Plex AAV6 Cartridge

There are currently no reviews for this product. Be the first to review Simple Plex AAV6 Cartridge and earn rewards!

Have you used Simple Plex AAV6 Cartridge?

Submit a review and receive an Amazon gift card.

$25/€18/£15/$25CAN/¥75 Yuan/¥1250 Yen for a review with an image

$10/€7/£6/$10 CAD/¥70 Yuan/¥1110 Yen for a review without an image

Submit a Review