Mouse Siglec‑F Alexa Fluor™ Plus 488‑conjugated Antibody

R&D Systems | Catalog # AF1706AFP488

R&D Systems

Key Product Details

Species Reactivity

Mouse

Applications

Western Blot

Label

Alexa Fluor Plus 488 (Excitation = 493 nm, Emission = 518 nm)

Antibody Source

Polyclonal Goat IgG
Loading...

Product Specifications

Specificity

Detects mouse Siglec-F in direct ELISAs and Western blots. In direct ELISAs and Western blots, less than 1% cross‑reactivity with recombinant mouse (rm) Siglec-2, rmSiglec-3, recombinant human (rh) Siglec-5, rhSiglec-7, rhSiglec-9, and rhSiglec-10 is observed.

Clonality

Polyclonal

Host

Goat

Isotype

IgG

Applications for Mouse Siglec‑F Alexa Fluor™ Plus 488‑conjugated Antibody

Application
Recommended Usage

Western Blot

Optimal dilution of this antibody should be experimentally determined.

Formulation, Preparation, and Storage

Formulation

Supplied 0.2 mg/mL in a saline solution containing BSA and Sodium Azide.

Shipping

The product is shipped with polar packs. Upon receipt, store it immediately at the temperature recommended below.

Stability & Storage

Protect from light. Do not freeze. 12 months from date of receipt, 2 to 8 °C as supplied

Background: Siglec-F

Siglecs (1) (sialic acid binding Ig-like lectins) are I-type (Ig-type) lectins (2) belonging to the Ig superfamily. They are characterized by an N-terminal Ig-like V-type domain which mediates sialic acid binding (3), followed by varying numbers of Ig-like C2-type domains (1, 4). Eleven human Siglecs have been cloned and characterized (1, 4). They are sialoadhesin/CD169/Siglec-1, CD22/Siglec-2, CD33/Siglec-3, Myelin-Associated Glycoprotein (MAG/Siglec-4a) and Siglec 5 to 11 (4‑6). To date, no Siglec has been shown to recognized any cell surface ligand other than sialic acids, suggesting that interactions with glycans containing this carbohydrate are important in mediating the biological functions of Siglecs. Siglec 5 to 11 share a high degree of sequence similarity with CD33/Siglec-3 both in their extracellular and intracellular regions. They are collectively referred to as CD33-related Siglecs. One remarkable feature of the CD33-related Siglecs is their differential expression pattern within the hematopoietic system (4, 5). This fact, together with the presence of two conserved immunoreceptor tyrosine-based inhibition motifs (ITIMs) in their cytoplasmic tails, suggests that CD33-related Siglecs are involved in the regulation of cellular activation within the immune system. Mouse Siglec-F cDNA encodes a 569 amino acid polypeptide with a hydrophobic signal peptide, an N-terminal Ig-like V-type domain, three Ig-like C2-type domains, a transmembrane region and a cytoplasmic tail (7). The expression of Siglec-F is restricted to the cells of myelomonocytic lineage. Mouse Siglec-F is likely an ortholog of human Siglec-5. Unlike many human CD33-related Siglecs, which show similar binding to both alpha 2,3- and alpha 2,6-linked sialic acids, mouse Siglec-F preferentially recognize alpha 2,3-linked sialic acid.

References

  1. Crocker, P.R. et al. (1998) Glycobiology 8:v.
  2. Powell, L.D. et al. (1995) J. Biol. Chem. 270:14243.
  3. May, A.R. et al. (1998) Mol. Cell 1998. 1:719.
  4. Crocker, P.R. and A. Varki (2001) Trends Immunol. 22:337.
  5. Crocker, P.R. et al. (2001) Immunology 103:137.
  6. Angata, T. et al. (2002) J. Biol Chem. 277:24466.
  7. Angata, T. et al. (2001) J. Biol Chem. 276:45128.

Long Name

Sialic Acid Binding Ig-like Lectin F

Alternate Names

SiglecF

Entrez Gene IDs

233186 (Mouse)

Gene Symbol

SIGLECF

UniProt

Additional Siglec-F Products

Product Documents for Mouse Siglec‑F Alexa Fluor™ Plus 488‑conjugated Antibody

Certificate of Analysis

To download a Certificate of Analysis, please enter a lot or batch number in the search box below.

Note: Certificate of Analysis not available for kit components.

Product Specific Notices for Mouse Siglec‑F Alexa Fluor™ Plus 488‑conjugated Antibody


This product is provided under an intellectual property license from Life Technologies Corporation. The transfer of this product is conditioned on the buyer using the purchased product solely in research conducted by the buyer, excluding contract research or any fee for service research, and the buyer must not (1) use this product or its components for (a) diagnostic, therapeutic or prophylactic purposes; (b) testing, analysis or screening services, or information in return for compensation on a per-test basis; or (c) manufacturing or quality assurance or quality control, and/or (2) sell or transfer this product or its components for resale, whether or not resold for use in research. For information on purchasing a license to this product for purposes other than as described above, contact Life Technologies Corporation, 5781 Van Allen Way, Carlsbad, CA 92008 USA or outlicensing@thermofisher.com.

For research use only

Customer Reviews

There are currently no reviews for this product. Be the first to review Mouse Siglec‑F Alexa Fluor™ Plus 488‑conjugated Antibody and earn rewards!

Have you used Mouse Siglec‑F Alexa Fluor™ Plus 488‑conjugated Antibody?

Submit a review and receive an Amazon gift card!

$25/€18/£15/$25CAN/¥2500 Yen for a review with an image

$10/€7/£6/$10CAN/¥1110 Yen for a review without an image

Submit a review
Amazon Gift Card

FAQs

No product specific FAQs exist for this product.

View all FAQs for Antibodies
Loading...