Key Product Details

Assay Length

90 minutes

Sample Type & Volume Required Per Well*

Cell Culture Supernates (25 µL), Serum (25 µL), EDTA Plasma (25 µL), Heparin Plasma (25 µL), Urine (25 µL), Cerebrospinal Fluid (25 µL)

Sensitivity

0.186 pg/mL

Assay Range

0.6-920 pg/mL (Cell Culture Supernates, Serum, EDTA Plasma, Heparin Plasma, Urine, Cerebrospinal Fluid)

Simple Plex Human CXCL10/IP-10 Cartridge Summary

Simple Plex assay for the detection of human Interferon gamma Inducible Protein 10 (IP-10) in cell culture supernatant (CCS), serum, plasma (EDTA/Heparin), urine, and cerebrospinal fluid (CSF).

*The Sample Volume represented is based on the amount of sample incorporated into the reaction after taking into account the assay's minimum required dilution for a given matrix. Serial dilution may be necessary to achieve some of the final sample volumes represented.

Compatible Instruments

Ella Automated Immunoassay System

Ella Automated Immunoassay System

Efficiently analyze biomarkers with Ella's advanced technology, providing accurate, precise results in under 90 minutes. Quantify up to 8 targets per assay through a streamlined automated workflow. Choose from >350 highly validated Simple Plex assays or Simple Plex discovery assays.
Loading...

Product Specifications

Assay Type

Automated sandwich ELISA

Format

Microfluidic cartridge containing three Glass Nano Reactors (GNR)

Species

Human

Specificity

Natural and recombinant human IP-10.

Cross-reactivity

Cross-reactivity observed with 1 or more available related molecules. < 50% cross-species reactivity observed with species tested.

Interference

No significant interference observed with available related molecules.

Precision

Intra-Assay Precision (Precision within an assay) Each control was tested 16 times in one assay.

Inter-Assay Precision (Precision between assays) Replicates of each control were tested in multiple assays performed by at least three technicians using two lots of reagents.

Cell Culture Supernates, Cerebrospinal Fluid, EDTA Plasma, Heparin Plasma, Serum, Urine

Intra-Assay Precision Inter-Assay Precision
Sample 1 2 1 2
n 16 16 14 12
Mean (pg/mL) 5.56 283 5.49 297
Standard Deviation 0.347 14.3 0.212 11.7
CV% 6.1 5.0 3.9 3.9

Recovery for Simple Plex Human CXCL10/IP-10 Cartridge

Recovery at three different spiked concentrations within the range of the assay was evaluated.

Sample Type Average % Recovery Range %
EDTA Plasma (n=4) 87 74-105
Heparin Plasma (n=4) 92 85-103
Serum (n=4) 93 80-107
Urine (n=8) 100 90-115

Linearity

Samples containing and/or spiked with high concentrations of human IP-10 were serially diluted with Sample Diluent to produce samples within the dynamic range of the assay.

Human IP-10 Simple Plex Assay Linearity

Scientific Data Images for Simple Plex Human CXCL10/IP-10 Cartridge

Human IP-10 Simple Plex Assay Standard Curve

Human IP-10 Simple Plex Assay Standard Curve

Preparation and Storage

Shipping

The product is shipped with polar packs. Upon receipt, store it immediately at the temperature recommended below.

Stability & Storage

Store the unopened product at 2 - 8 °C. Do not use past expiration date.

Background: CXCL10/IP-10/CRG-2

CXCL10/IP-10 is an ELR- angiostatic chemokine that interacts with CXCR3 to attract Th1 cells, eosinophils, monocytes, and NK cells to sites of inflammation. It is upregulated by activated T lymphocytes, neutrophils, splenocytes, keratinocytes, osteoblasts, astrocytes, endothelial cells, smooth muscle cells, and pancreatic beta cells. CXCL10 contributes to disease pathology in many chronic inflammatory disorders including rheumatoid arthritis, psoriasis, cancer, multiple sclerosis, diabetes, and cardiovascular disease.

Alternate Names

CRG-2, CRG2, IP-10

Entrez Gene IDs

3627 (Human); 15945 (Mouse)

Gene Symbol

CXCL10

Additional CXCL10/IP-10/CRG-2 Products

Product Documents for Simple Plex Human CXCL10/IP-10 Cartridge

Loading product document information...

Loading product document information...

Certificate of Analysis

To download a Certificate of Analysis, please enter your Simple Plex catalog number and lot number in the search boxes below.

Product Specific Notices for Simple Plex Human CXCL10/IP-10 Cartridge

For research use only

Citations for Simple Plex Human CXCL10/IP-10 Cartridge

View all citations for the Simple Plex platform.

Please visit our Instrument Citation Database to search our collection of scientific articles that feature our instruments.

Customer Reviews for Simple Plex Human CXCL10/IP-10 Cartridge

There are currently no reviews for this product. Be the first to review Simple Plex Human CXCL10/IP-10 Cartridge and earn rewards!

Have you used Simple Plex Human CXCL10/IP-10 Cartridge?

Submit a review and receive an Amazon gift card!

$25/€18/£15/$25CAN/¥2500 Yen for a review with an image

$10/€7/£6/$10CAN/¥1110 Yen for a review without an image

Submit a review
Amazon Gift Card