MauriceFlex System
Automated icIEF, CE‑SDS, and Charge Variant Fractionation
Automated icIEF, icIEF Fractionation, and CE-SDS on One System
MauriceFlex™ system is an automated capillary electrophoresis system that combines icIEF, icIEF‑based fractionation, and CE‑SDS on a single platform. In addition to routine charge and size analysis, MauriceFlex enables collection of charge variants for in-depth characterization using a variety of downstream methods, such as intact mass spectrometry, reduced-MS, peptide mapping, binding analysis with SPR, aggregate analysis with mass photometry and other orthogonal analytical techniques.
How can MauriceFlex System Help you?
Simplify Charge Variant Analysis
- icIEF fractionation enables separation and collection of charge variants on the same system, eliminating the need for methods like ion-exchange chromatography (IEX)
- Fractions are collected in ammonium acetate and do not contain urea, and can thus be analyzed with mass spectrometry without additional sample preparation
- The collected fractions can be characterized by various analytical instruments without needing buffer exchange
Biomolecular and Protein Fractionation on MauriceFlex
Get a deeper characterization of charge variants with fractionation
- An applied electric field creates a pH gradient across the capillary inside the MauriceFlex cartridge
- Proteins separate by migrating to different pH values on the gradient, based on their individual isoelectric point (pI)
- Introduction of ammonium acetate chargers the pH gradient, mobilizing these separated proteins, and results in elution (fractionation)
MauriceFlex Specifications for icIEF, and cIEF Fractionation
| Feature | cIEF | cIEF 400 | cIEF Fractionation |
| Minimum Sample Volume | 50 µL | 50 µL | 100 µL |
| Sample Delivery | Vacuum | Vacuum | Vacuum |
| Typical Separation Time | 6–10 min (molecule-dependent) | 6–10 min (molecule-dependent) | 40 – 50 min (molecule-dependent) |
| Detection Capability | UV Absorbance at 280 nm Fluorescence: Ex 280 nm, Em 320– 450 nm | UV Absorbance at 280 nm Fluorescence: Ex 280 nm, Em 320– 450 nm | Fluorescence: Ex 280 nm, Em 320-450nm |
| Typical Voltage | Pre-focusing: 1500 V, focusing: 3000 V | Pre-focusing: 1500 V, focusing: 3000 V | Pre-focusing: 500 V and 1000 V Focusing: 1500 V |
| Sample Injections per Cartridge | 200 maximum (max 25 batches) | 400 maximum (max 40 batches) | Maximum 15 injections |
| Maximum Sample Injections per Batch | 100 | 100 | 1 (fractionation) 4 (cIEF) |
| pI/Size Range | 2.85–10.45 | 2.85–10.45 | 3-10 |
| pI/Sizing CV | 1% | 1% | 1% |
| CV for Peaks >10% Composition | ≤5% (Intra-batch), ≤6% (Inter-batch) | ≤5% (Intra-batch), ≤6% (Inter-batch) | ≤10% (Inter-batch) |
| pI/Sizing Resolution | 0.05 pI units (for wide range 3–10 ampholytes) | 0.05 pI units (for wide range 3–10 ampholytes) | |
| Dynamic Range | 2 logs | 2 logs | |
| Linearity | >0.995 | >0.995 | |
| Sensitivity (LOD) | 0.7 µg/mL (Native fluorescence) 3.0 µg / mL(Absorbance) (Values based on a monoclonal antibody) | 0.7 µg/mL (Native fluorescence) 3.0 µg / mL(Absorbance) (Values based on a monoclonal antibody) |
MauriceFlex Specifications for CE-SDS
| Feature | CE-SDS PLUS | Turbo CE-SDS |
| Minimum Sample Volume | 50 µL | 100 µL |
| Sample Delivery | Electrokinetic | Electrokinetic |
| Typical Separation Time | Reduced IgG: 25 min, Non-reduced IgG: 35 min | Reduced IgG: 5.5 min Non-reduced IgG: 8 min |
| Detection Capability | UV Absorbance at 220 nm | UV Absorbance at 220 nm |
| Typical Voltage | Separation: 5750 V | Separation: 4200 V |
| Sample Injections per Cartridge | 500 maximum (max 25 batches) | max 25 batches |
| Maximum Sample Injections per Batch | 48 | 96 |
| pI/Size Range | 10–270 kDa | 10–270 kDa |
| pI/Sizing CV | ≤2% | <2% |
| CV for Peaks >10% Composition | N/A | N/A |
| Relative Migration Time CV | <1% for reduced IgG | <5% |
| pI/Sizing Resolution | ≥1.5 for NGHC/HC IgG Standard | ≥1.0 for NGHC/HC IgG Standard |
| Dynamic Range | 2 logs | 2 logs |
| Linearity | >0.995 | >0.995 |
| Sensitivity (LOD) | 0.3 µg/mL (Value based on Internal Standard) | 0.6 µg/mL (Value based on Internal Standard) |
| Sample Tray Options | 96-well plates or 48 vials (cIEF Fractionation: 96-well plates only) |
| Power | 100 V–240 V (AC), 50/60 Hz, 500 W |
| Voltage Range | 0–6,500 V |
| Temperature Control Range | 4-25 °C (cIEF Fractionation: 10-25 °C) |
| Dimensions | 44cm H x 42cm W x 61cm D |
| Weight | 46 kg (100 lb) |
Compatible Products
| Product | Catalog Number |
| MauriceFlex System | 090-158 |
| CE-SDS PLUS Cartridge | PS-MC02-SP |
| Turbo CE-SDS Cartridge | PS-MC02-TS |
| CE-SDS PLUS Application Kit | PS-MAK03-S |
| Turbo CE-SDS Application Kit | PS-MAK01-TS |
| cIEF Cartridge | PS-MC02-C |
| icIEF 400 Cartridge | PS-MC02-400C |
| cIEF Method Development Kit | PS-MDK01-C |
| cIEF Fractionation Application Kit | PS-MAK01-F |
| cIEF Fractionation Cartridge | PS-MC02-F |