Human Adiponectin/Acrp30 Magnetic Luminex® Performance Assay

R&D Systems | Catalog # LOBM1065

R&D Systems

Luminex High Performance Assays

Human Adiponectin/Acrp30 Magnetic Luminex® Performance Assay is specifically designed for multiplex detection of human Adiponectin/Acrp30 with a panel of related analytes in serum, plasma, or tissue culture supernatants. Luminex High Performance Assays go through rigorous development, validation, and quality control testing to ensure the best performance of your multiplex assay.

This assay is customizable, select some or all the analytes in the entire panel. Customize your panel with the Luminex Assay Customization Tool.


Key Product Details

Panel

Human Obesity Panel

Assay Type

Magnetic bead-based multiplex assay for the Luminex® platform

Format

1 x 96-well microplate and magnetic antibody-coated beads

Species

Human

Analytes Detected

Adiponectin/Acrp30

Not finding your analyte of interest? View our complete Luminex offering in the full version of our Luminex Assay Customization Tool. We also offer Custom Luminex Services.

Build Your Assay

Make Selections Below to Configure Your Custom Luminex® Assay

Filter Analytes
Select All Select None

Configured Assays

Below are kits that are available based on your selections. These selections may be further customized before adding to the cart or emailing the configuration to your purchasing department or local distributor to place your order. Selected analytes may be included in more than one High Performance Assay. All assay options are displayed.

If overlapping bead regions occur in analyte selections, send your Luminex configuration code to our team for resolution.

How would you like these analytes mixed?

Premixed
User Mixed
Please select at least one mixing option to see the kits.

Would you like to split based on sample dilution?

Do not split
Split based on serum
Split based on plasma
Split based on cell culture supernates
Loading...

Product Features

Magnetic Luminex High Performance Assays are flexible bead-based multiplex assays. They allow up to 50 user-defined target analytes to be simultaneously profiled using cell culture supernates, serum, or plasma samples. Some panels are also validated with human milk, saliva, and/or urine samples.

  • Simultaneously profile Human Adiponectin/Acrp30 with a panel of related analytes in one sample
  • Magnetic format allows for easier wash steps
  • Undergoes similar validation testing as Quantikine® ELISA Kits
  • Precise and Specific
  • Requires a small sample volume (<50 µL)
  • Run your assay in just 3-5 hours
  • Mass-calibrated standards for consistent results with every new lot of material
  • Enough reagents for one 96-well plate
  • Quick turn-around time: Kits are typically shipped within 2-3 days of ordering*

*Please allow additional time for international orders.

Performance Validation

R&D Systems Luminex High Performance Assays undergo our most extensive validation testing. All Luminex High Performance Assay Panels are validated for use with serum and plasma samples. Some High Performance Assays are additionally validated for cell culture supernatants, milk, saliva, or urine, as indicated on the individual product data sheets. Luminex High Performance Assays are tested for sensitivity (three-quarters the low standard), intra-assay precision, inter-assay precision, and to ensure assay linearity for validated sample types. Recovery values for individual samples in validated sample types are also tested. Validation data for each analyte can be found in the product datasheet.

Base Kit Contents

  • Standard Cocktail(s)
  • Bead Diluent
  • Biotin Antibody Diluent
  • Calibrator Diluent
  • Wash Buffer
  • Streptavidin-PE
  • One flat-bottom 96-well Microplate
  • Foil Plate Sealers (4)
  • Mixing Bottle
  • Standard Value Card**

**A standard curve must be generated each time an assay is run, utilizing values from the Certificate of Analysis provided with each Luminex Assay.

Bead Set Contents

  • User-mixed antibody-coated Magnetic beads in individual vials
  • User-mixed cocktail of biotinylated detection antibody

Precision

Intra-assay Precision (precision within an assay) - Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision. Inter-assay Precision (precision between assays) - Three samples of known concentration were tested in twenty separate assays to assess precision between assays.

  Intra-Assay Precision Inter-Assay Precision
Sample 1 2 3 1 2 3
n 20 20 20 20 20 20
Mean (pg/mL) 449 1490 6735 500 1631 6854
Standard deviation 22 42 376 73 212 629
CV (%) 5.0 2.8 5.6 14.6 13.0 6.2
 

Recovery

Samples containing and/or spiked with human Adiponectin were evaluated for recovery.

Sample Type Average % Recovery Range (%)
Cell culture supernate 85 67-95
 

Linearity

Samples containing and/or spiked with human Adiponectin were serially diluted to evaluate assay linearity.

  Cell culture supernate Serum EDTA plasma Heparin plasma
1:2 Average % of Expected 112 101 103 103
Range (%) 102-126 86-106 78-123 76-130
1:4 Average % of Expected 115 100 97 112
Range (%) 107-126 91-112 73-119 93-136
1:8 Average % of Expected 115 93 97 103
Range (%) 99-142 86-103 75-114 93-115

Which Luminex Assay is Right for Me?

Assays for the Luminex platform are offered as High Performance Assays or Discovery Assays.

High Performance Assays are optimized and validated as complete panels with a focused set of analytes. You can choose from Fixed Panels, Premixed options, or Configurable User Mix formats depending on your needs.

Discovery Assays deliver maximum flexibility, enabling the creation of fully customized panels tailored to your research needs. With universal reagents validated for compatibility across all analytes in the menu, they support endless customization possibilities.

Additional Information About Luminex Assays

All R&D Systems Luminex Assays are designed for use with any Luminex instrument including MAGPIX, Luminex 200, FLEXMAP 3D, and the INTELLIFLEX.

Luminex assays use color-coded, magnetic microparticles coated with analyte-specific antibodies to enable multiplex quantitation. During the assay, standards and samples are added to the wells, where target analytes bind to the capture antibodies. A biotinylated detection antibody cocktail is then introduced, followed by a Streptavidin-PE conjugate that generates a fluorescent signal proportional to the amount of analyte present.

Each microparticle is identified by a unique signature and the signal intensity is measured using a Luminex instrument. These assays are designed to deliver reliable and reproducible results with validated antibody pairs and optimized protocols. They are well suited for applications that require sensitivity, accuracy, and confidence in your data while enabling efficient multiplexing to measure multiple targets simultaneously.

Scientific Data Images for Human Adiponectin/Acrp30 Magnetic Luminex® Performance Assay

Quantist software graph of signal intensity versus concentration for Adiponectin/Acrp30 in the Human Obesity Luminex Panel

Preparation and Storage

Shipping

The product is shipped at ambient temperature. Upon receipt, store it immediately at the temperature recommended below.

Stability & Storage

Store the unopened product at 2 - 8 °C. Do not use past expiration date.

Background: Adiponectin/Acrp30

Adiponectin (Acrp30) is secreted primarily by adipocytes and induces multiple paracrine and endocrine effects on metabolism and inflammation. Adiponectin promotes insulin sensitivity, decreased serum glucose and triglyceride levels, and increased serum glucagon levels. It promotes fatty acid uptake and oxidation, glucose uptake, and lactate production in skeletal muscle. Adiponectin promotes the development of M2 macrophages and promotes the C1qRp mediated clearance of apoptotic cell debris. Decreased plasma HMW Adiponectin levels are associated with upper body obesity, insulin resistance, reduced fatty acid oxidation, dyslipidemia, coronary artery disease, and atherogenesis. Adiponectin forms homotrimers, hexamers, and high molecular weight (HMW) complexes and signals through the receptors AdipoR1 and AdipoR2.

Alternate Names

Acrp30, AdipoQ, ApM1, GBP28

Entrez Gene IDs

9370 (Human); 11450 (Mouse); 246253 (Rat)

Gene Symbol

ADIPOQ

Additional Adiponectin/Acrp30 Products

Product Documents for Human Adiponectin/Acrp30 Magnetic Luminex® Performance Assay

Certificate of Analysis

To download a Certificate of Analysis, please enter a lot or batch number in the search box below.

Note: Certificate of Analysis not available for kit components.

Product Specific Notices for Human Adiponectin/Acrp30 Magnetic Luminex® Performance Assay

Luminex® is a registered trademark of Luminex Corporation.

For research use only

Citations for Human Adiponectin/Acrp30 Magnetic Luminex® Performance Assay

Customer Reviews for Human Adiponectin/Acrp30 Magnetic Luminex® Performance Assay (2)

5 out of 5
2 Customer Ratings
5 Stars
100%
4 Stars
0%
3 Stars
0%
2 Stars
0%
1 Stars
0%

Have you used Human Adiponectin/Acrp30 Magnetic Luminex® Performance Assay?

Submit a review and receive an Amazon gift card!

$25/€18/£15/$25CAN/¥2500 Yen for a review with an image

$10/€7/£6/$10CAN/¥1110 Yen for a review without an image

Submit a review
Amazon Gift Card

Customer Images


Showing  1 - 2 of 2 reviews Showing All
Filter By:
  • Human Adiponectin/Acrp30 Magnetic Luminex Performance Assay
    Name: Anonymous
    Sample Tested: Saliva
    Verified Customer | Posted 02/08/2019
    Human Adiponectin/Acrp30 Magnetic Luminex® Performance Assay LOBM1065
  • Human Adiponectin/Acrp30 Magnetic Luminex Performance Assay
    Name: Anonymous
    Sample Tested: Saliva
    Verified Customer | Posted 01/22/2019
    Human Adiponectin/Acrp30 Magnetic Luminex® Performance Assay LOBM1065

There are no reviews that match your criteria.

Showing  1 - 2 of 2 reviews Showing All

FAQs

No product specific FAQs exist for this product.

View all FAQs for Luminex Assays