Human GM-CSF XL Luminex® Performance Assay

R&D Systems | Catalog # LUXLM215

R&D Systems

Luminex High Performance Assays

Human GM-CSF XL Luminex® Performance Assay is specifically designed for multiplex detection of human GM-CSF with a panel of related analytes in serum, plasma, or tissue culture supernatants. Luminex High Performance Assays go through rigorous development, validation, and quality control testing to ensure the best performance of your multiplex assay.

This assay is customizable, select some or all the analytes in the entire panel. Customize your panel with the Luminex Assay Customization Tool.


Key Product Details

Panel

Human XL Cytokine Panel

Assay Type

Magnetic bead-based multiplex assay for the Luminex® platform

Format

1 x 96-well microplate and magnetic antibody-coated beads

Species

Human

Analytes Detected

GM-CSF

Not finding your analyte of interest? View our complete Luminex offering in the full version of our Luminex Assay Customization Tool. We also offer Custom Luminex Services.

Build Your Assay

Make Selections Below to Configure Your Custom Luminex® Assay

Filter Analytes
Select All Select None

Configured Assays

Below are kits that are available based on your selections. These selections may be further customized before adding to the cart or emailing the configuration to your purchasing department or local distributor to place your order. Selected analytes may be included in more than one High Performance Assay. All assay options are displayed.

If overlapping bead regions occur in analyte selections, send your Luminex configuration code to our team for resolution.

How would you like these analytes mixed?

Premixed
User Mixed
Please select at least one mixing option to see the kits.

Would you like to split based on sample dilution?

Do not split
Split based on serum
Split based on plasma
Split based on cell culture supernates
Loading...

Product Features

Magnetic Luminex High Performance Assays are flexible bead-based multiplex assays. They allow up to 50 user-defined target analytes to be simultaneously profiled using cell culture supernates, serum, or plasma samples. Some panels are also validated with human milk, saliva, and/or urine samples.

  • Simultaneously profile Human GM-CSF with a panel of related analytes in one sample
  • Magnetic format allows for easier wash steps
  • Undergoes similar validation testing as Quantikine® ELISA Kits
  • Precise and Specific
  • Requires a small sample volume (<50 µL)
  • Run your assay in just 3-5 hours
  • Mass-calibrated standards for consistent results with every new lot of material
  • Enough reagents for one 96-well plate
  • Quick turn-around time: Kits are typically shipped within 2-3 days of ordering*

*Please allow additional time for international orders.

Performance Validation

R&D Systems Luminex High Performance Assays undergo our most extensive validation testing. All Luminex High Performance Assay Panels are validated for use with serum and plasma samples. Some High Performance Assays are additionally validated for cell culture supernatants, milk, saliva, or urine, as indicated on the individual product data sheets. Luminex High Performance Assays are tested for sensitivity (three-quarters the low standard), intra-assay precision, inter-assay precision, and to ensure assay linearity for validated sample types. Recovery values for individual samples in validated sample types are also tested. Validation data for each analyte can be found in the product datasheet.

View Luminex High Performance Human XL validation data.

Base Kit Contents

  • Premixed cocktail of biotinylated detection antibody
  • Standard Cocktail(s)
  • Bead Diluent
  • Biotin Antibody Diluent
  • Calibrator Diluent
  • Wash Buffer
  • Streptavidin-PE
  • One flat-bottom 96-well Microplate
  • Foil Plate Sealers (4)
  • Mixing Bottle
  • Standard Value Card**
  • High and low controls with Control Mean Value Card

**A standard curve must be generated each time an assay is run, utilizing values from the Certificate of Analysis provided with each Luminex Assay.

Bead Set Contents

  • User-mixed antibody-coated Magnetic beads in individual vials

Recommended Sample Types: Cell culture supernates, serum, EDTA plasma, and heparin plasma

Components: Human GM-CSF Magnetic Microparticles (Part 898830) is supplied as a 100X concentrated stock (0.075 mL) with preservatives. Other Supplies Required: Magnetic Luminex® Performance Assay Human XL Discovery Base Kit (R&D Systems®, Catalog # LUXLM000).

Sensitivity: The Minimum Detectable Dose (MDD) was determined by adding two standard deviations to the mean MFI of twenty zero standard replicates and calculating the corresponding concentration. Six assays were evaluated, and the MDD of human GM-CSF ranged from 0.855-3.82 pg/mL. The mean MDD was 1.56 pg/mL.

Correlation: This assay has been correlated to the Quantikine® ELISA Kit.

Specificity: This assay recognizes natural and recombinant human GM-CSF.

Bead Region: 37  

Precision

Intra-assay Precision (precision within an assay) - Two samples of known concentration were tested twenty times on one plate to assess intra-assay precision. Inter-assay Precision (precision between assays) - Two samples of known concentration were tested in thirty separate assays to assess precision between assays.

  Intra-Assay Precision Inter-Assay Precision
Sample 1 2 1 2
n 20 20 30 30
Mean (pg/mL) 197 1829 197 1,863
Standard deviation 6.62 63.3 29.6 139
CV (%) 36.0 3.4 14.9 47.1
 

Recovery

Samples containing and/or spiked with human GM-CSF were evaluated for recovery.

Sample Type Average % Recovery Range (%)
Cell culture supernate 118 106-132
Serum 97.7 89.6-109
EDTA plasma 100 95.1-106
Heparin plasma 97.6 91.3-104
Plaelet-poor EDTA 111 85.6-133
Platelet-poor Heparin 109 93.2-124
 

Linearity

Samples containing and/or spiked with human GM-CSF were serially diluted to evaluate assay linearity.

  Cell culture supernate Serum EDTA plasma Heparin plasma Platelet-poor EDTA Platelet-poor Heparin
1:2 Average % of Expected 97.8 103 100 102 102 102
Range (%) 91.4-103 100-106 97.0-106 100-105 95.8-109 98.8-105
1:4 Average % of Expected 92.6 99.0 95.9 97.1 102 102  
Range (%) 85.1-98.9 95.5-101 88.6-105 93.2-103 93.7-109 92.0-117
1:8 Average % of Expected 93.4 102 98.3 99.5 110 100
Range (%) 89.8-98.3 97.5-104 93.3-107 94.2-106 97.5-124 96.7-106
1:16 Average % of Expected 93.8 99.7 96.0 95.0 104 93.7
Range (%) 90.6-97.4 92.9-105 87.1-104 91.9-102 96.8-114 88.0-101

Which Luminex Assay is Right for Me?

Assays for the Luminex platform are offered as High Performance Assays or Discovery Assays.

High Performance Assays are optimized and validated as complete panels with a focused set of analytes. You can choose from Fixed Panels, Premixed options, or Configurable User Mix formats depending on your needs.

Discovery Assays deliver maximum flexibility, enabling the creation of fully customized panels tailored to your research needs. With universal reagents validated for compatibility across all analytes in the menu, they support endless customization possibilities.

Additional Information About Luminex Assays

All R&D Systems Luminex Assays are designed for use with any Luminex instrument including MAGPIX, Luminex 200, FLEXMAP 3D, and the INTELLIFLEX.

Luminex assays use color-coded, magnetic microparticles coated with analyte-specific antibodies to enable multiplex quantitation. During the assay, standards and samples are added to the wells, where target analytes bind to the capture antibodies. A biotinylated detection antibody cocktail is then introduced, followed by a Streptavidin-PE conjugate that generates a fluorescent signal proportional to the amount of analyte present.

Each microparticle is identified by a unique signature and the signal intensity is measured using a Luminex instrument. These assays are designed to deliver reliable and reproducible results with validated antibody pairs and optimized protocols. They are well suited for applications that require sensitivity, accuracy, and confidence in your data while enabling efficient multiplexing to measure multiple targets simultaneously.

Scientific Data Images for Human GM-CSF XL Luminex® Performance Assay

GM-CSF XL Cytokine Luminex Panel Standard Curves

Preparation and Storage

Shipping

The product is shipped at ambient temperature. Upon receipt, store it immediately at the temperature recommended below.

Stability & Storage

Store the unopened product at 2 - 8 °C. Do not use past expiration date.

Background: GM-CSF

GM-CSF (Granulocyte-Macrophage Colony Stimulating Factor) induces the development of monocytes, neutrophils, eosinophils, and myeloid and dermal dendritic cells. It also acts as a neutrophil and dendritic cell chemoattractant. GM-CSF promotes Th1 and Th17 cell mediated autoimmune inflammation as well as the inflammatory activation of dendritic cells, microglia, alveolar macrophages, and eosinophils. In addition, it cooperates with G-CSF in promoting tumor cell proliferation and invasion. GM-CSF signals through a receptor complex composed of GM-CSF R alpha and the Common beta Chain (beta c) with Syndecan-2 as a potential co-receptor. The beta c subunit is shared by the receptor complexes for IL-3 and IL-5.

Long Name

Granulocyte Macrophage Growth Factor

Alternate Names

CSF-2, CSF2, GMCSF, Molgramostim, Sargramostim

Entrez Gene IDs

1437 (Human); 12981 (Mouse); 116630 (Rat); 397208 (Porcine); 403923 (Canine); 493805 (Feline)

Gene Symbol

CSF2

Additional GM-CSF Products

Product Documents for Human GM-CSF XL Luminex® Performance Assay

Certificate of Analysis

To download a Certificate of Analysis, please enter a lot or batch number in the search box below.

Note: Certificate of Analysis not available for kit components.

Product Specific Notices for Human GM-CSF XL Luminex® Performance Assay

Luminex® is a registered trademark of Luminex Corporation.

For research use only

Citations for Human GM-CSF XL Luminex® Performance Assay

Customer Reviews for Human GM-CSF XL Luminex® Performance Assay

There are currently no reviews for this product. Be the first to review Human GM-CSF XL Luminex® Performance Assay and earn rewards!

Have you used Human GM-CSF XL Luminex® Performance Assay?

Submit a review and receive an Amazon gift card!

$25/€18/£15/$25CAN/¥2500 Yen for a review with an image

$10/€7/£6/$10CAN/¥1110 Yen for a review without an image

Submit a review
Amazon Gift Card

FAQs

No product specific FAQs exist for this product.

View all FAQs for Luminex Assays