CCL2/JE/MCP-1, is a chemokine that binds the receptor CCR2 and induces the chemoattraction of mononuclear cells. It induces the activation of monocytes, NK cells, lymphocytes, and basophils. Additionally, CCL2 promotes Th2 polarization in CD4+ T cells, and CCL2-mediated recruitment of monocytes to sites of inflammation contributes to disease severity in atherosclerosis, multiple sclerosis, and allergic asthma. Endogenous proteolytic trimming of CCL2 at the N-terminus, including the N-terminal pyrrolidone carboxylic acid-modified glutamine, downregulates activity but not receptor binding.
Mouse CCL2/JE/MCP-1 Quantikine ELISA Kit
R&D Systems | Catalog # MJE00B
Key Product Details
Assay Length
Sample Type & Volume Required Per Well
Sensitivity
Assay Range
Product Summary for Mouse CCL2/JE/MCP-1 Quantikine ELISA Kit
Product Specifications
Measurement
Detection Method
Conjugate
Species
Specificity
Cross-reactivity
Interference
Precision
Intra-Assay Precision (Precision within an assay) Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-Assay Precision (Precision between assays) Three samples of known concentration were tested in twenty separate assays to assess inter-assay precision. Assays were performed by at least three technicians.
Cell Culture Supernates, EDTA Plasma, Heparin Plasma, Serum, Tissue Culture Supernates, Tissue Lysates
| Intra-Assay Precision | Inter-Assay Precision | |||||
|---|---|---|---|---|---|---|
| Sample | 1 | 2 | 3 | 1 | 2 | 3 |
| n | 20 | 20 | 20 | 20 | 20 | 20 |
| Mean (pg/mL) | 36.7 | 51.8 | 149 | 37.8 | 60.0 | 155 |
| Standard Deviation | 1.45 | 1.40 | 3.66 | 2.85 | 4.37 | 7.86 |
| CV% | 4.0 | 2.7 | 2.5 | 7.5 | 7.3 | 5.1 |
Recovery for Mouse CCL2/JE/MCP-1 Quantikine ELISA Kit
The recovery of mouse MCP-1 spiked to three levels throughout the range of the assay in various matrices was evaluated.
| Sample Type | Average % Recovery | Range % |
|---|---|---|
| Cell Culture Media (n=4) | 105 | 95-112 |
| Cell Lysis Buffer (n=4) | 88 | 79-101 |
| EDTA Plasma (n=4) | 84 | 75-93 |
| Heparin Plasma (n=4) | 93 | 80-101 |
| Serum (n=4) | 91 | 83-100 |
Linearity
To assess the linearity of the assay, samples containing and/or spiked with high concentrations of mouse MCP-1 were serially diluted with calibrator diluent to produce samples with values within the dynamic range of the assay.
Scientific Data Images for Mouse CCL2/JE/MCP-1 Quantikine ELISA Kit
Mouse CCL2/JE/MCP-1 ELISA Standard Curve
Mouse/Rat CCL2/JE/MCP-1 Standard Curve
Preparation and Storage
Shipping
Stability & Storage
Background: CCL2/JE/MCP-1
Alternate Names
Gene Symbol
Additional CCL2/JE/MCP-1 Products
Product Documents for Mouse CCL2/JE/MCP-1 Quantikine ELISA Kit
Certificate of Analysis
To download a Certificate of Analysis, please enter a lot or batch number in the search box below.
Note: Certificate of Analysis not available for kit components.
Product Specific Notices for Mouse CCL2/JE/MCP-1 Quantikine ELISA Kit
For research use only
⚠ WARNING: This product can expose you to chemicals including N,N-Dimethylforamide, which is known to the State of California to cause cancer. For more information, go to www.P65Warnings.ca.gov.Citations for Mouse CCL2/JE/MCP-1 Quantikine ELISA Kit
Customer Reviews for Mouse CCL2/JE/MCP-1 Quantikine ELISA Kit (6)
Have you used Mouse CCL2/JE/MCP-1 Quantikine ELISA Kit?
Submit a review and receive an Amazon gift card!
$25/€18/£15/$25CAN/¥2500 Yen for a review with an image
$10/€7/£6/$10CAN/¥1110 Yen for a review without an image
Submit a review
Customer Images
-
Sample Tested: lysate from mouse spinal cordVerified Customer | Posted 09/29/2024Please check figure S10 of the following paper, Scientific Reports volume 9, Article number: 17728 (2019)
-
Sample Tested: Aorta tissueVerified Customer | Posted 07/25/2023
-
Sample Tested: SerumVerified Customer | Posted 05/04/2023
-
Sample Tested: Serum-free Cell Culture MediaVerified Customer | Posted 12/02/2021
-
Sample Tested: Serum-free Cell Culture MediaVerified Customer | Posted 10/21/2021
-
Sample Tested: Cell Culture MediaVerified Customer | Posted 08/06/2018I had to dilute the samples more than recommended, but the result was as expected
There are no reviews that match your criteria.
Protocols
Find general support by application which include: protocols, troubleshooting, illustrated assays, videos and webinars.
- ELISA Sample Preparation & Collection Guide
- ELISA Troubleshooting Guide
- How to Run an R&D Systems DuoSet ELISA
- How to Run an R&D Systems Quantikine ELISA
- How to Run an R&D Systems Quantikine™ QuicKit™ ELISA
- Quantikine HS ELISA Kit Assay Principle, Alkaline Phosphatase
- Quantikine HS ELISA Kit Principle, Streptavidin-HRP Polymer
- Sandwich ELISA (Colorimetric) – Biotin/Streptavidin Detection Protocol
- Sandwich ELISA (Colorimetric) – Direct Detection Protocol
- Troubleshooting Guide: ELISA
- View all Protocols, Troubleshooting, Illustrated assays and Webinars