Human B7-H7/HHLA2 Antibody (907812)
R&D Systems | Catalog # MAB80841
Scientific images may be resized, cropped, or adjusted for brightness or contrast for presentation purposes. These updates are limited to presentation and do not affect the underlying scientific interpretation of the data. Where available, additional source data may be provided upon request.
Key Product Details
Species Reactivity
Applications
Label
Antibody Source
Product Specifications
Immunogen
Met1-Asn344
Accession # Q9UM44
Specificity
Clonality
Host
Isotype
Endotoxin Level
Scientific Data Images for Human B7-H7/HHLA2 Antibody (907812)
Detection of B7-H7/HHLA2 in HEK Human Cell Line Transfected with Human B7-H7/HHLA2 and eGFP by Flow Cytometry.
HEK293 human embryonic kidney cell line transfected with either (A) human B7-H7/HHLA2 or (B) irrelevant protein, and eGFP was stained with Mouse Anti-Human B7-H7/HHLA2 Monoclonal Antibody (Catalog # MAB80841) followed by anti-Mouse IgG APC-conjugated secondary antibody (Catalog # F0101B). Quadrant markers were set based on control antibody staining (Catalog # MAB002). View our protocol for Staining Membrane-associated Proteins.B7-H7/HHLA2 in Human PBMCs.
B7-H7/HHLA2 was detected in immersion fixed human peripheral blood mononuclear cells (PBMCs) using Mouse Anti-Human B7-H7/HHLA2 Monoclonal Antibody (Catalog # MAB80841) at 25 µg/mL for 3 hours at room temperature. Cells were stained using the NorthernLights™ 557-conjugated Anti-Mouse IgG Secondary Antibody (red; Catalog # NL007) and counterstained with DAPI (blue). Specific staining was localized to cytoplasm. View our protocol for Fluorescent ICC Staining of Non-adherent Cells.TMIGD2/CD28H Binding to B7-H7/ HHLA2-transfected HEK293 Human Cell Line is Blocked by Human B7-H7/HHLA2 Antibody.
In a functional flow cytometry test, biotinylated recombinant human TMIGD2/ CD28H (10 ng/mL, Catalog # 8316-TR) binds to HEK293 human embryonic kidney cell line transfected with human B7-H7/ HHLA2 (black dotted line). Binding is completely blocked (orange histogram) by 2.5 µg/mL of Mouse Anti-Human B7-H7/ HHLA2 Monoclonal Antibody (Catalog # MAB80841). Mouse IgG1 Isotype Control (Catalog # MAB002) at 2.5 µg/mL was used as a control (blue line). Cells were stained with Streptavidin-APC (Catalog # F0050).B7-H7 Binding to TMIGD2/ CD28H Blocked by Human B7-H7/HHLA2 Antibody.
In a Surface Plasmon Resonance test, Recombinant Human TMIGD2/ CD28H Fc Chimera (Catalog # 8316-TR), coated at 10 ng/mL binds to Recombinant Human B7-H7/HHLA2 Fc Chimera (Catalog # 8084-B7, 5 µg/mL) (blue line). Binding is completely blocked (red) by 50 µg/mL of Mouse Anti-Human B7-H7/ HHLA2 Monoclonal Antibody (Catalog # MAB80841). Mouse IgG1 isotype (Catalog # MAB002) and irrelevant mouse monoclonal antibody were used as controls and did not affect TMIGD2/ CD28H binding to B7-H7/HHLA2 (not shown).Applications for Human B7-H7/HHLA2 Antibody (907812)
Blockade of Receptor-ligand Interaction
(100 µL/well). At 1.25 μg/mL, this antibody will block >90% of the binding.
CyTOF-ready
Flow Cytometry
Sample: HEK Human Cell Line Transfected with Human B7-H7/HHLA2 and eGFP
Immunocytochemistry
Sample: Immersion fixed human peripheral blood mononuclear cells (PBMCs)
Flow Cytometry Panel Builder
Bio-Techne Knows Flow Cytometry
Save time and reduce costly mistakes by quickly finding compatible reagents using the Panel Builder Tool.
Advanced Features
- Spectra Viewer - Custom analysis of spectra from multiple fluorochromes
- Spillover Popups - Visualize the spectra of individual fluorochromes
- Antigen Density Selector - Match fluorochrome brightness with antigen density
Formulation, Preparation, and Storage
Purification
Reconstitution
Reconstitute at 0.5 mg/mL in sterile PBS. For liquid material, refer to CoA for concentration.
Formulation
Shipping
Stability & Storage
- 12 months from date of receipt, -20 to -70 °C as supplied.
- 1 month, 2 to 8 °C under sterile conditions after reconstitution.
- 6 months, -20 to -70 °C under sterile conditions after reconstitution.
Calculators
Background: B7-H7/HHLA2
B7‑H7 is constitutively expressed on monocytes and is up-regulated by LPS and IFN-gamma stimulation. It is expressed on LPS/IFN-gamma treated B cells but not on resting B cells (5). B7-H7 binds to cell surface determinants on resting and mature T cells, B cells, and monocytes as well as on immature and mature dendritic cells (5). Soluble B7-H7 inhibits the proliferation of activated CD4+ and CD8+ T cells and their production of IFN-gamma, TNF-alpha, IL-5, IL-10, IL-13, IL-17A, and IL-22 (5).
References
- Zou, W. and L. Chen (2008) Nat. Rev. Immunol. 8:467.
- Bour-Jordan, H. et al. (2011) Immunol. Rev. 241:180.
- Mager, D.L. et al. (1999) Genomics 59:255.
- Flajnik, M.M. et al. (2012) Immunogenetics 64:571.
- Zhao, R. et al. (2013) Proc. Natl. Acad. Sci. USA 110:9879.
Long Name
Alternate Names
Gene Symbol
UniProt
Additional B7-H7/HHLA2 Products
Product Documents for Human B7-H7/HHLA2 Antibody (907812)
Certificate of Analysis
To download a Certificate of Analysis, please enter a lot or batch number in the search box below.
Note: Certificate of Analysis not available for kit components.
Product Specific Notices for Human B7-H7/HHLA2 Antibody (907812)
For research use only
Related Research Areas
Citations for Human B7-H7/HHLA2 Antibody (907812)
Customer Reviews for Human B7-H7/HHLA2 Antibody (907812)
There are currently no reviews for this product. Be the first to review Human B7-H7/HHLA2 Antibody (907812) and earn rewards!
Have you used Human B7-H7/HHLA2 Antibody (907812)?
Submit a review and receive an Amazon gift card!
$25/€18/£15/$25CAN/¥2500 for a review with an image
$10/€7/£6/$10CAN/¥1110 for a review without an image
Submit a review
Protocols
Find general support by application which include: protocols, troubleshooting, illustrated assays, videos and webinars.
- 7-Amino Actinomycin D (7-AAD) Cell Viability Flow Cytometry Protocol
- Appropriate Fixation of IHC/ICC Samples
- Cellular Response to Hypoxia Protocols
- ClariTSA™ Fluorophore Kits
- Detection & Visualization of Antibody Binding
- Extracellular Membrane Flow Cytometry Protocol
- Flow Cytometry Protocol for Cell Surface Markers
- Flow Cytometry Protocol for Staining Membrane Associated Proteins
- Flow Cytometry Staining Protocols
- Flow Cytometry Troubleshooting Guide
- ICC Cell Smear Protocol for Suspension Cells
- ICC Immunocytochemistry Protocol Videos
- ICC for Adherent Cells
- Immunocytochemistry (ICC) Protocol
- Immunocytochemistry Troubleshooting
- Immunofluorescence of Organoids Embedded in Cultrex Basement Membrane Extract
- Immunohistochemistry (IHC) and Immunocytochemistry (ICC) Protocols
- Intracellular Flow Cytometry Protocol Using Alcohol (Methanol)
- Intracellular Flow Cytometry Protocol Using Detergents
- Intracellular Nuclear Staining Flow Cytometry Protocol Using Detergents
- Intracellular Staining Flow Cytometry Protocol Using Alcohol Permeabilization
- Intracellular Staining Flow Cytometry Protocol Using Detergents to Permeabilize Cells
- Preparing Samples for IHC/ICC Experiments
- Preventing Non-Specific Staining (Non-Specific Binding)
- Primary Antibody Selection & Optimization
- Propidium Iodide Cell Viability Flow Cytometry Protocol
- Protocol for Liperfluo
- Protocol for VisUCyte™ HRP Polymer Detection Reagent
- Protocol for the Characterization of Human Th22 Cells
- Protocol for the Characterization of Human Th9 Cells
- Protocol for the Fluorescent ICC Staining of Cell Smears - Graphic
- Protocol for the Fluorescent ICC Staining of Cultured Cells on Coverslips - Graphic
- Protocol for the Preparation and Fluorescent ICC Staining of Cells on Coverslips
- Protocol for the Preparation and Fluorescent ICC Staining of Non-adherent Cells
- Protocol for the Preparation and Fluorescent ICC Staining of Stem Cells on Coverslips
- Protocol for the Preparation of a Cell Smear for Non-adherent Cell ICC - Graphic
- Protocol: Annexin V and PI Staining by Flow Cytometry
- Protocol: Annexin V and PI Staining for Apoptosis by Flow Cytometry
- TUNEL and Active Caspase-3 Detection by IHC/ICC Protocol
- The Importance of IHC/ICC Controls
- Troubleshooting Guide: Fluorokine Flow Cytometry Kits
- View all Protocols, Troubleshooting, Illustrated assays and Webinars