Key Product Details
Species Reactivity
Human, Feline
Applications
Flow Cytometry, Immunofluorescence, Immunocytochemistry/ Immunofluorescence
Label
Unconjugated
Antibody Source
Monoclonal Mouse IgG2b Kappa Clone # HuLy-m1
Loading...
Product Specifications
Immunogen
Human thymocytes (Uniprot: P06729)
Localization
Cell surface
Clonality
Monoclonal
Host
Mouse
Isotype
IgG2b Kappa
Theoretical MW
50 kDa.
Disclaimer note: The observed molecular weight of the protein may vary from the listed predicted molecular weight due to post translational modifications, post translation cleavages, relative charges, and other experimental factors.
Disclaimer note: The observed molecular weight of the protein may vary from the listed predicted molecular weight due to post translational modifications, post translation cleavages, relative charges, and other experimental factors.
Description
200ug/ml of antibody purified from Bioreactor Concentrate by Protein A or G. Prepared in 10 mM PBS with 0.05% BSA & 0.05% azide. Also available WITHOUT BSA & azide at 1.0 mg/ml. (NBP2-47979)
Antibody with azide - store at 2 to 8C. Antibody without azide - store at -20 to -80C.
Antibody with azide - store at 2 to 8C. Antibody without azide - store at -20 to -80C.
Scientific Data Images for CD2 Antibody (HuLy-m1)
Immunocytochemistry/ Immunofluorescence: CD2 Antibody (HuLy-m1) [NBP2-44908]
Immunocytochemistry/Immunofluorescence: CD2 Antibody (HuLy-m1) [NBP2-44908] - Analysis of CD2 antibody (HuLy-m1) on Jurkat cells. Image from verified customer review.Flow Cytometry: CD2 Antibody (HuLy-m1) [NBP2-44908]
Flow Cytometry: CD2 Antibody (HuLy-m1) [NBP2-44908] - Flow Cytometric Analysis of MOLT-4 cells using CD2 Antibody (HuLy-m1) followed by goat anti-Mouse IgG-CF488 (Blue); Isotype Control (Red).Flow Cytometry: CD2 Antibody (HuLy-m1) [NBP2-44908]
Flow Cytometry: CD2 Antibody (HuLy-m1) [NBP2-44908] - The cat whole blood cells are washed and incubated with CD2 antibody. This antibody was used to detect Tcell s in cat species. This image was submitted via customer review. Image from the PE version of this antibody.Applications for CD2 Antibody (HuLy-m1)
Application
Recommended Usage
Flow Cytometry
1-2 ug/million cells
Immunocytochemistry/ Immunofluorescence
1-2 ug/ml
Immunofluorescence
0.5 - 1.0 ug/ml
Application Notes
Optimal dilution for a specific application should be determined.
Reviewed Applications
Read 1 review rated 5 using NBP2-44908 in the following applications:
Flow Cytometry Panel Builder
Bio-Techne Knows Flow Cytometry
Save time and reduce costly mistakes by quickly finding compatible reagents using the Panel Builder Tool.
Advanced Features
- Spectra Viewer - Custom analysis of spectra from multiple fluorochromes
- Spillover Popups - Visualize the spectra of individual fluorochromes
- Antigen Density Selector - Match fluorochrome brightness with antigen density
Formulation, Preparation, and Storage
Purification
Protein A or G purified
Formulation
10 mM PBS with 0.05% BSA
Preservative
0.05% Sodium Azide
Concentration
0.2 mg/ml
Shipping
The product is shipped with polar packs. Upon receipt, store it immediately at the temperature recommended below.
Stability & Storage
Store at 4C.
Background: CD2
The CD2-CD58 interaction has been shown to play a role in anti-tumor immune response, where reduced CD58 signaling is associated with immune escape of tumor cells in various hematological and lymphoid malignancies, but restoration of the signal promotes an anti-tumor response (2,5). Additionally, following cytomegalovirus (CMV) infection, CD2's binding to upregulated CD58 on CMV-infected cells is crucial for the activation and function of adaptive NK cells in the anti-viral response (2). In contrast, in situations where there is an increase in T cell and NK cell activation, like various autoimmune disorders or following organ transplant, costimulatory blockade of CD2-CD58 may be a potential therapeutic treatment approach (1). Mouse and rat xenograft models have shown that blocking the CD2 using anti-CD2 monoclonal antibodies contributes to graft survival and protects against lymphocyte infiltration and inflammatory damage (2).
References
1. Binder C, Cvetkovski F, Sellberg F, et al. CD2 Immunobiology. Front Immunol. 2020;11:1090. https://doi.org/10.3389/fimmu.2020.01090
2. Zhang Y, Liu Q, Yang S, Liao Q. CD58 Immunobiology at a Glance. Front Immunol. 2021;12:705260. https://doi.org/10.3389/fimmu.2021.705260
3. Uniprot (P06729)
4. van der Merwe PA. A subtle role for CD2 in T cell antigen recognition. J Exp Med. 1999;190(10):1371-1374. https://doi.org/10.1084/jem.190.10.1371
5. Nishikori M, Kitawaki T, Tashima M, Shimazu Y, Mori M, et al. Diminished CD2 Expression in T cells Permits Tumor Immune Escape. J Clin Cell Immunol. 2016;7:406. https://doi.org/10.4172/2155-9899.1000406
Additional CD2 Products
Product Documents for CD2 Antibody (HuLy-m1)
Product Specific Notices for CD2 Antibody (HuLy-m1)
This product is for research use only and is not approved for use in humans or in clinical diagnosis. Primary Antibodies are guaranteed for 1 year from date of receipt.
Customer Reviews for CD2 Antibody (HuLy-m1) (1)
5 out of 5
1 Customer Rating
Have you used CD2 Antibody (HuLy-m1)?
Submit a review and receive an Amazon gift card!
$25/€18/£15/$25CAN/¥2500 Yen for a review with an image
$10/€7/£6/$10CAN/¥1110 Yen for a review without an image
Submit a review
Customer Images
Showing
1
-
1 of
1 review
Showing All
Filter By:
-
Application: ImmunocytochemistrySample Tested: Jurkat cellsSpecies: HumanVerified Customer | Posted 06/28/2022Jurkat cells
There are no reviews that match your criteria.
Protocols
Find general support by application which include: protocols, troubleshooting, illustrated assays, videos and webinars.
- 7-Amino Actinomycin D (7-AAD) Cell Viability Flow Cytometry Protocol
- Appropriate Fixation of IHC/ICC Samples
- Cellular Response to Hypoxia Protocols
- Detection & Visualization of Antibody Binding
- Extracellular Membrane Flow Cytometry Protocol
- Flow Cytometry Protocol for Cell Surface Markers
- Flow Cytometry Protocol for Staining Membrane Associated Proteins
- Flow Cytometry Staining Protocols
- Flow Cytometry Troubleshooting Guide
- ICC Cell Smear Protocol for Suspension Cells
- ICC Immunocytochemistry Protocol Videos
- ICC for Adherent Cells
- Immunocytochemistry (ICC) Protocol
- Immunocytochemistry Troubleshooting
- Immunofluorescence of Organoids Embedded in Cultrex Basement Membrane Extract
- Immunohistochemistry (IHC) and Immunocytochemistry (ICC) Protocols
- Intracellular Flow Cytometry Protocol Using Alcohol (Methanol)
- Intracellular Flow Cytometry Protocol Using Detergents
- Intracellular Nuclear Staining Flow Cytometry Protocol Using Detergents
- Intracellular Staining Flow Cytometry Protocol Using Alcohol Permeabilization
- Intracellular Staining Flow Cytometry Protocol Using Detergents to Permeabilize Cells
- Preparing Samples for IHC/ICC Experiments
- Preventing Non-Specific Staining (Non-Specific Binding)
- Primary Antibody Selection & Optimization
- Propidium Iodide Cell Viability Flow Cytometry Protocol
- Protocol for VisUCyte™ HRP Polymer Detection Reagent
- Protocol for the Characterization of Human Th22 Cells
- Protocol for the Characterization of Human Th9 Cells
- Protocol for the Fluorescent ICC Staining of Cell Smears - Graphic
- Protocol for the Fluorescent ICC Staining of Cultured Cells on Coverslips - Graphic
- Protocol for the Preparation and Fluorescent ICC Staining of Cells on Coverslips
- Protocol for the Preparation and Fluorescent ICC Staining of Non-adherent Cells
- Protocol for the Preparation and Fluorescent ICC Staining of Stem Cells on Coverslips
- Protocol for the Preparation of a Cell Smear for Non-adherent Cell ICC - Graphic
- Protocol: Annexin V and PI Staining by Flow Cytometry
- Protocol: Annexin V and PI Staining for Apoptosis by Flow Cytometry
- TUNEL and Active Caspase-3 Detection by IHC/ICC Protocol
- The Importance of IHC/ICC Controls
- Troubleshooting Guide: Fluorokine Flow Cytometry Kits
- View all Protocols, Troubleshooting, Illustrated assays and Webinars
Loading...