  • Assay Type
    Solid Phase Sandwich ELISA
  • Format
    96-well strip plate
  • Assay Length
    4.5 hours
  • Sample Type & Volume Required Per Well
    Cell Culture Supernates (100 uL), Serum (100 uL), EDTA Plasma (100 uL), Heparin Plasma (100 uL), Citrate Plasma (100 uL), Urine (100 uL)
  • Sensitivity
    4.39 pg/mL
  • Assay Range
    15.6 - 1,000 pg/mL (Cell Culture Supernates, Serum, EDTA Plasma, Heparin Plasma, Citrate Plasma, Urine)
  • Specificity
    Natural and recombinant human CA9
  • Cross-reactivity
    < 0.5% cross-reactivity observed with available related molecules.< 50% cross-species reactivity observed with species tested.
  • Interference
    No significant interference observed with available related molecules.
Control Available
QC24 , Quantikine Immunoassay Control Group 9 - Please Inquire
Product Summary
The Quantikine Human Carbonic Anhydrase IX Immunoassay is a 4.5 hour solid-phase ELISA designed to measure human CA9 in cell culture supernates, serum, plasma, and urine. It contains NS0-expressed recombinant human CA9 ectodomain and has been shown to accurately quantitate the recombinant factor. Results obtained using natural human CA9 showed linear curves that were parallel to the standard curves obtained using the Quantikine kit standards. These results indicate that this kit can be used to determine relative mass values for naturally occurring human CA9.

Precision
Intra-Assay Precision (Precision within an assay) Three samples of known concentration were tested on one plate to assess intra-assay precision
Inter-Assay Precision (Precision between assays) Three samples of known concentration were tested in separate assays to assess inter-assay precision
Cell Culture Supernates, Serum, EDTA Plasma, Heparin Plasma, Citrate Plasma, Urine
Intra-Assay Precision Inter-Assay Precision
Sample 1 2 3 1 2 3
n 20 20 20 40 40 40
Mean 166 338 673 166 333 647
Standard Deviation 6.36 7.19 20.5 10.5 21.6 39.7
CV% 3.8 2.1 3 6.3 6.5 6.1

Recovery

The recovery of CA9 spiked to levels throughout the range of the assay in various matrices was evaluated.

Sample Type Average % Recovery Range %
Cell Culture Media (n=4) 110 103-114
Citrate Plasma (n=4) 96 89-111
EDTA Plasma (n=4) 99 90-110
Heparin Plasma (n=4) 97 88-112
Serum (n=4) 97 87-106
Urine (n=4) 101 89-114
Linearity
To assess the linearity of the assay, samples containing and/or spiked with high concentrations of CA9 were serially diluted with the Calibrator Diluent to produce samples with values within the dynamic range of the assay.
 Carbonic Anhydrase IX/CA9 [HRP]
Product Datasheets

Certificate of Analysis Lookup

To download a Certificate of Analysis, please enter a lot number in the search box below.

Note: Certificate of Analysis not available for kit components.

Certificate of Analysis Lookup

Certificate of Analysis Request Form

To download a Certificate of Analysis, please enter the catalog and lot numbers in the search box below.

Note: Certificate of Analysis not available for kit components.

Preparation and Storage
  • Storage
    Store the unopened product at 2 - 8 °C. Do not use past expiration date.
Background: Carbonic Anhydrase IX/CA9
Carbonic anhydrases catalyze the reversible reaction of CO2 + H2O = HCO3- + H+, which is fundamental to many processes such as respiration, renal tubular acidification and bone resorption. Human members of the CAs are secreted (CA6), membrane-bound (CA4, 9 to 12 and 14), cytosolic (CA1 to 3, 7, 8 and 13) or mitochondrial (CA5A and 5B). Some CAs may serve as markers for tumors and hypoxia. A subset of CAs lack CA activity due to point mutations but retain esterase function.
  • Entrez Gene IDs:
    768 (Human); 230099 (Mouse)
  • Alternate Names:
    CA9; CA-IX; CAIXcarbonic anhydrase 9; Carbonate dehydratase IX; Carbonic Anhydrase IX; carbonic anhydrase IXpMW1; carbonic dehydratase; EC 4.2.1.1; G250; Membrane antigen MN; MN; MNRCC-associated antigen G250; P54/58N; RCC; RCC-associated protein G250; Renal cell carcinoma-associated antigen G250
Related Research Areas
Assay Procedure
Refer to the product for complete assay procedure.

Bring all reagents and samples to room temperature before use. It is recommended that all samples, standards, and controls be assayed in duplicate.
  1.   Prepare all reagents, standard dilutions, and samples as directed in the product insert.
  2.   Remove excess microplate strips from the plate frame, return them to the foil pouch containing the desiccant pack, and reseal.

  3. 50 µL Assay Diluent
  4.   Add 50 µL of Assay Diluent to each well.

  5. 100 µL Standard, Control, or Sample
  6.   Add 100 µL of Standard, control, or sample to each well. Cover with a plate sealer, and incubate at room temperature for 2 hours on a horizontal orbital microplate shaker.
  7.   Aspirate each well and wash, repeating the process 3 times for a total of 4 washes.

  8. 200 µL Conjugate
  9.   Add 200 µL of Conjugate to each well. Cover with a new plate sealer, and incubate at room temperature for 2 hours on the shaker.
  10.   Aspirate and wash 4 times.

  11. 200 µL Substrate Solution
  12.   Add 200 µL Substrate Solution to each well. Incubate at room temperature for 30 minutes on the benchtop. PROTECT FROM LIGHT.

  13. 50 µL Stop Solution
  14.   Add 50 µL of Stop Solution to each well. Read at 450 nm within 30 minutes. Set wavelength correction to 540 nm or 570 nm.
Citations:

R&D Systems personnel manually curate a database that contains references using R&D Systems products. The data collected includes not only links to publications in PubMed, but also provides information about sample types, species, and experimental conditions.

9 Citations: Showing 1 - 9
Filter your results:

Species
Sample Type
  1. Small cell lung cancer: model of circulating tumor cell tumorospheres in chemoresistance
    Authors: L Klameth, B Rath, M Hochmaier, D Moser, M Redl, F Mungenast, K Gelles, E Ulsperger, R Zeillinger, G Hamilton
    Sci Rep, 2017;7(1):5337.
    Species: Human
    Sample Type: Cell Culture Supernates
  2. A multiplex immunoassay for the non-invasive detection of bladder cancer.
    Authors: Shimizu Y, Furuya H, Bryant Greenwood P, Chan O, Dai Y, Thornquist M, Goodison S, Rosser C
    J Transl Med, 2016;14(1):31.
    Species: Human
    Sample Type: Urine
  3. DNA-linked Inhibitor Antibody Assay (DIANA) for sensitive and selective enzyme detection and inhibitor screening
    Nucleic Acids Res, 2016;0(0):.
    Species: Human
    Sample Type: Cell Lysates
  4. Prognostic utility of pre-operative circulating osteopontin, carbonic anhydrase IX and CRP in renal cell carcinoma.
    Br. J. Cancer, 2012;107(7):1131-7.
    Species: Human
    Sample Type: Plasma
  5. A multi-analyte assay for the non-invasive detection of bladder cancer.
    Authors: Goodison, Steve, Chang, Myron, Dai, Yunfeng, Urquidi, Virginia, Rosser, Charles
    PLoS ONE, 2012;7(10):e47469.
    Species: Human
    Sample Type: Urine
  6. Measuring carbonic anhydrase IX as a hypoxia biomarker: differences in concentrations in serum and plasma using a commercial enzyme-linked immunosorbent assay due to influences of metal ions.
    Authors: Wind TC, Messenger MP, Thompson D, Selby PJ, Banks RE
    Ann. Clin. Biochem., 2011;48(0):112-20.
    Species: Human
    Sample Type: Serum
  7. Myeloid Biomarkers Associated with Glioblastoma Response to Anti-VEGF Therapy with Aflibercept.
    Authors: de Groot JF, Piao Y, Tran H, Gilbert M, Wu HK, Liu J, Bekele BN, Cloughesy T, Mehta M, Robins HI, Lassman A, Deangelis L, Camphausen K, Chen A, Yung W, Prados M, Wen PY, Heymach JV
    Clin. Cancer Res., 2011;17(14):4872-4881.
    Species: Human
    Sample Type: Plasma
  8. High levels of carbonic anhydrase IX in tumour tissue and plasma are biomarkers of poor prognostic in patients with non-small cell lung cancer.
    Authors: Ilie M, Mazure NM, Hofman V, Ammadi RE, Ortholan C, Bonnetaud C, Havet K, Venissac N, Mograbi B, Mouroux J, Pouyssegur J, Hofman P
    Br. J. Cancer, 2010;102(11):1627-35.
    Species: Human
    Sample Type: Plasma
  9. Expression of carbonic anhydrase 9, a potential intrinsic marker of hypoxia, is associated with poor prognosis in oesophageal squamous cell carcinoma.
    Authors: Tanaka N, Kato H, Inose T, Kimura H, Faried A, Sohda M, Nakajima M, Fukai Y, Miyazaki T, Masuda N, Fukuchi M, Kuwano H
    Br. J. Cancer, 2008;99(9):1468-75.
    Species: Human
    Sample Type: Cell Culture Supernates

FAQs

No product specific FAQs exist for this product, however you may

View all ELISA FAQs
ELISA Controls
Description Application Cat# Citations Images  

Quantikine Immunoassay Control Group 9

Ctrl QC24  
View Sizes & Prices
Catalog# Size Price Stock Quantity
Loading Information....
Supplemental ELISA Products
Description Application Cat# Citations Images  

Quantikine ELISA Wash Buffer 1

ELISA WA126 6  
View Sizes & Prices
Catalog# Size Price Stock Quantity
Loading Information....
Average Rating: 5 (Based on 1 review)

Have you used Human Carbonic Anhydrase IX Quantikine ELISA Kit?

Submit a review and receive a $25US/€18/£15/$25CAN amazon gift card if you include an image - $10US/€7/£6/$10CAN Amazon card for reviews without an image. Limited to verified customers in USA, Canada and Europe.

Read what people are saying who have used Human Carbonic Anhydrase IX Quantikine ELISA Kit.

Filter by Ratings
Excellent
(1)
All Ratings
Filter by Applications
All Applications
Filter by Species
All Species

Images Ratings Applications Species Reviewed By Date Details
 Human Carbonic Anhydrase IX Quantikine ELISA Kit DCA900 Array DCA900
Enlarge
Excellent
  Anonymous 02/21/2018
Show
Image Details
 Human Carbonic Anhydrase IX Quantikine ELISA Kit DCA900
: Human Carbonic Anhydrase IX Quantikine ELISA Kit [DCA900].

Summary

Sample Tested Human plasma samples

Other Experimental Details

Other Experimental Details Used 100 ul of Standard, control and plasma samples in duplicates.

Please scroll the above reviews for more

Order Details