Key Product Details
Species Reactivity
Human, Mouse, Rat
Applications
Western Blot, Immunocytochemistry
Label
Unconjugated
Antibody Source
Monoclonal Mouse IgG1 Clone # 730340
Loading...
Product Specifications
Immunogen
E. coli-derived recombinant human EMP/MAEA
Met12-Ser66
Accession # Q7L5Y9
Met12-Ser66
Accession # Q7L5Y9
Specificity
Detects human EMP/MAEA in direct ELISAs and Western blots.
Clonality
Monoclonal
Host
Mouse
Isotype
IgG1
Scientific Data Images for Human/Mouse/Rat EMP/MAEA Antibody
Detection of Human, Mouse, and Rat EMP/MAEA by Western Blot.
Western blot shows lysates of Jurkat human acute T cell leukemia cell line, K562 human chronic myelogenous leukemia cell line, C2C12 mouse myoblast cell line, NR8383 rat alveolar macrophage cell line, and Y3‑Ag rat myeloid cell line. PVDF membrane was probed with 0.5 µg/mL of Mouse Anti-Human/Mouse/Rat EMP/MAEA Monoclonal Antibody (Catalog # MAB7288) followed by HRP-conjugated Anti-Mouse IgG Secondary Antibody (Catalog # HAF007). Specific bands were detected for EMP/MAEA at approximately 36-45 kDa (as indicated). This experiment was conducted under reducing conditions and using Immunoblot Buffer Group 1.EMP/MAEA in Jurkat Human Cell Line.
EMP/MAEA was detected in immersion fixed Jurkat human acute T cell leukemia cell line using Mouse Anti-Human/Mouse/Rat EMP/MAEA Monoclonal Antibody (Catalog # MAB7288) at 10 µg/mL for 3 hours at room temperature. Cells were stained using the NorthernLights™ 557-conjugated Anti-Mouse IgG Secondary Antibody (red, upper panel; Catalog # NL007) and counterstained with DAPI (blue, lower panel). Specific staining was localized to cell surfaces and cytoplasm. View our protocol for Fluorescent ICC Staining of Cells on Coverslips. This application has not been tested in mouse or rat samples.Applications for Human/Mouse/Rat EMP/MAEA Antibody
Application
Recommended Usage
Immunocytochemistry
8-25 µg/mL
Sample: Immersion fixed Jurkat human acute T cell leukemia cell line
Sample: Immersion fixed Jurkat human acute T cell leukemia cell line
Western Blot
0.5 µg/mL
Sample: Jurkat human acute T cell leukemia cell line, K562 human chronic myelogenous leukemia cell line, C2C12 mouse myoblast cell line, NR8383 rat alveolar macrophage cell line, and Y3‑Ag rat myeloid cell line
Sample: Jurkat human acute T cell leukemia cell line, K562 human chronic myelogenous leukemia cell line, C2C12 mouse myoblast cell line, NR8383 rat alveolar macrophage cell line, and Y3‑Ag rat myeloid cell line
Formulation, Preparation, and Storage
Purification
Protein A or G purified from hybridoma culture supernatant
Reconstitution
Sterile PBS to a final concentration of 0.5 mg/mL. For liquid material, refer to CoA for concentration.
Formulation
Lyophilized from a 0.2 μm filtered solution in PBS with Trehalose. *Small pack size (SP) is supplied either lyophilized or as a 0.2 µm filtered solution in PBS.
Shipping
Lyophilized product is shipped at ambient temperature. Liquid small pack size (-SP) is shipped with polar packs. Upon receipt, store immediately at the temperature recommended below.
Stability & Storage
Use a manual defrost freezer and avoid repeated freeze-thaw cycles.
- 12 months from date of receipt, -20 to -70 °C as supplied.
- 1 month, 2 to 8 °C under sterile conditions after reconstitution.
- 6 months, -20 to -70 °C under sterile conditions after reconstitution.
Calculators
Background: EMP/MAEA
Long Name
Erythroblast Macrophage Protein/Macrophage Erythroblast Attacher
Alternate Names
EMLP, HLC-10, MAEA, PIG5
Gene Symbol
MAEA
UniProt
Additional EMP/MAEA Products
Product Documents for Human/Mouse/Rat EMP/MAEA Antibody
Certificate of Analysis
To download a Certificate of Analysis, please enter a lot or batch number in the search box below.
Note: Certificate of Analysis not available for kit components.
Product Specific Notices for Human/Mouse/Rat EMP/MAEA Antibody
For research use only
Related Research Areas
Customer Reviews for Human/Mouse/Rat EMP/MAEA Antibody
There are currently no reviews for this product. Be the first to review Human/Mouse/Rat EMP/MAEA Antibody and earn rewards!
Have you used Human/Mouse/Rat EMP/MAEA Antibody?
Submit a review and receive an Amazon gift card!
$25/€18/£15/$25CAN/¥2500 Yen for a review with an image
$10/€7/£6/$10CAN/¥1110 Yen for a review without an image
Submit a review
Protocols
Find general support by application which include: protocols, troubleshooting, illustrated assays, videos and webinars.
- Appropriate Fixation of IHC/ICC Samples
- Cellular Response to Hypoxia Protocols
- ClariTSA™ Fluorophore Kits
- Detection & Visualization of Antibody Binding
- ICC Cell Smear Protocol for Suspension Cells
- ICC Immunocytochemistry Protocol Videos
- ICC for Adherent Cells
- Immunocytochemistry (ICC) Protocol
- Immunocytochemistry Troubleshooting
- Immunofluorescence of Organoids Embedded in Cultrex Basement Membrane Extract
- Immunohistochemistry (IHC) and Immunocytochemistry (ICC) Protocols
- Preparing Samples for IHC/ICC Experiments
- Preventing Non-Specific Staining (Non-Specific Binding)
- Primary Antibody Selection & Optimization
- Protocol for VisUCyte™ HRP Polymer Detection Reagent
- Protocol for the Fluorescent ICC Staining of Cell Smears - Graphic
- Protocol for the Fluorescent ICC Staining of Cultured Cells on Coverslips - Graphic
- Protocol for the Preparation and Fluorescent ICC Staining of Cells on Coverslips
- Protocol for the Preparation and Fluorescent ICC Staining of Non-adherent Cells
- Protocol for the Preparation and Fluorescent ICC Staining of Stem Cells on Coverslips
- Protocol for the Preparation of a Cell Smear for Non-adherent Cell ICC - Graphic
- R&D Systems Quality Control Western Blot Protocol
- TUNEL and Active Caspase-3 Detection by IHC/ICC Protocol
- The Importance of IHC/ICC Controls
- Troubleshooting Guide: Western Blot Figures
- Western Blot Conditions
- Western Blot Protocol
- Western Blot Protocol for Cell Lysates
- Western Blot Troubleshooting
- Western Blot Troubleshooting Guide
- View all Protocols, Troubleshooting, Illustrated assays and Webinars
Loading...