Scientific images may be resized, cropped, or adjusted for brightness or contrast for presentation purposes. These updates are limited to presentation and do not affect the underlying scientific interpretation of the data. Where available, additional source data may be provided upon request.
Key Product Details
Species Reactivity
Applications
Label
Antibody Source
Product Specifications
Immunogen
Met12-Ser66
Accession # Q7L5Y9
Specificity
Clonality
Host
Isotype
Scientific Data Images for EMP/MAEA Antibody (730340)
Detection of Human, Mouse, and Rat EMP/MAEA by Western Blot.
Western blot shows lysates of Jurkat human acute T cell leukemia cell line, K562 human chronic myelogenous leukemia cell line, C2C12 mouse myoblast cell line, NR8383 rat alveolar macrophage cell line, and Y3‑Ag rat myeloid cell line. PVDF membrane was probed with 0.5 µg/mL of Mouse Anti-Human/Mouse/Rat EMP/MAEA Monoclonal Antibody (Catalog # MAB7288) followed by HRP-conjugated Anti-Mouse IgG Secondary Antibody (Catalog # HAF007). Specific bands were detected for EMP/MAEA at approximately 36-45 kDa (as indicated). This experiment was conducted under reducing conditions and using Immunoblot Buffer Group 1.EMP/MAEA in Jurkat Human Cell Line.
EMP/MAEA was detected in immersion fixed Jurkat human acute T cell leukemia cell line using Mouse Anti-Human/Mouse/Rat EMP/MAEA Monoclonal Antibody (Catalog # MAB7288) at 10 µg/mL for 3 hours at room temperature. Cells were stained using the NorthernLights™ 557-conjugated Anti-Mouse IgG Secondary Antibody (red, upper panel; Catalog # NL007) and counterstained with DAPI (blue, lower panel). Specific staining was localized to cell surfaces and cytoplasm. View our protocol for Fluorescent ICC Staining of Cells on Coverslips. This application has not been tested in mouse or rat samples.Applications for EMP/MAEA Antibody (730340)
Immunocytochemistry
Sample: Immersion fixed Jurkat human acute T cell leukemia cell line
Western Blot
Sample: Jurkat human acute T cell leukemia cell line, K562 human chronic myelogenous leukemia cell line, C2C12 mouse myoblast cell line, NR8383 rat alveolar macrophage cell line, and Y3‑Ag rat myeloid cell line
Formulation, Preparation, and Storage
Purification
Reconstitution
Formulation
Shipping
Stability & Storage
- 12 months from date of receipt, -20 to -70 °C as supplied.
- 1 month, 2 to 8 °C under sterile conditions after reconstitution.
- 6 months, -20 to -70 °C under sterile conditions after reconstitution.
Calculators
Background: EMP/MAEA
Long Name
Alternate Names
Gene Symbol
UniProt
Additional EMP/MAEA Products
Product Documents for EMP/MAEA Antibody (730340)
Certificate of Analysis
To download a Certificate of Analysis, please enter a lot or batch number in the search box below.
Note: Certificate of Analysis not available for kit components.
Product Specific Notices for EMP/MAEA Antibody (730340)
For research use only
Related Research Areas
Customer Reviews for EMP/MAEA Antibody (730340)
There are currently no reviews for this product. Be the first to review EMP/MAEA Antibody (730340) and earn rewards!
Have you used EMP/MAEA Antibody (730340)?
Submit a review and receive an Amazon gift card!
$25/€18/£15/$25CAN/¥2500 for a review with an image
$10/€7/£6/$10CAN/¥1110 for a review without an image
Submit a review
Protocols
Find general support by application which include: protocols, troubleshooting, illustrated assays, videos and webinars.
- Appropriate Fixation of IHC/ICC Samples
- Cellular Response to Hypoxia Protocols
- ClariTSA™ Fluorophore Kits
- Detection & Visualization of Antibody Binding
- ICC Cell Smear Protocol for Suspension Cells
- ICC Immunocytochemistry Protocol Videos
- ICC for Adherent Cells
- Immunocytochemistry (ICC) Protocol
- Immunocytochemistry Troubleshooting
- Immunofluorescence of Organoids Embedded in Cultrex Basement Membrane Extract
- Immunohistochemistry (IHC) and Immunocytochemistry (ICC) Protocols
- Preparing Samples for IHC/ICC Experiments
- Preventing Non-Specific Staining (Non-Specific Binding)
- Primary Antibody Selection & Optimization
- Protocol for VisUCyte™ HRP Polymer Detection Reagent
- Protocol for the Fluorescent ICC Staining of Cell Smears - Graphic
- Protocol for the Fluorescent ICC Staining of Cultured Cells on Coverslips - Graphic
- Protocol for the Preparation and Fluorescent ICC Staining of Cells on Coverslips
- Protocol for the Preparation and Fluorescent ICC Staining of Non-adherent Cells
- Protocol for the Preparation and Fluorescent ICC Staining of Stem Cells on Coverslips
- Protocol for the Preparation of a Cell Smear for Non-adherent Cell ICC - Graphic
- R&D Systems Quality Control Western Blot Protocol
- TUNEL and Active Caspase-3 Detection by IHC/ICC Protocol
- The Importance of IHC/ICC Controls
- Troubleshooting Guide: Western Blot Figures
- Western Blot Conditions
- Western Blot Protocol
- Western Blot Protocol for Cell Lysates
- Western Blot Troubleshooting
- Western Blot Troubleshooting Guide
- View all Protocols, Troubleshooting, Illustrated assays and Webinars