Mouse IgG1 APC-conjugated Antibody

Catalog # Availability Size / Price Qty
IC002A
Detection of Mouse IgG Isotype Control by Flow Cytometry
1 Image
Product Details
Citations (24)
FAQs
Supplemental Products
Reviews (3)

Mouse IgG1 APC-conjugated Antibody Summary

Specificity
Selected for use as mouse IgG1 isotype control for flow cytometry applications.
Source
Monoclonal Mouse IgG1 kappa Clone # 11711
Purification
Protein A or G purified from hybridoma culture supernatant
Immunogen
KLH
Formulation
Supplied in a saline solution containing BSA and Sodium Azide.
Label
Allophycocyanin (Excitation= 620-650 nm, Emission= 660-670 nm)

Applications

Recommended Concentration
Sample
Control
Negative control for use in conjunction with R&D Systems antibodies. This isotype control has been derivatized with a quantity of fluorochrome that matched the F/P (fluorochrome/protein) ratio of R&D Systems monoclonal reagents. The recommended concentration is 10 μL/106 cells.
 

Please Note: Optimal dilutions should be determined by each laboratory for each application. General Protocols are available in the Technical Information section on our website.

Scientific Data

Detection of Mouse IgG Control by Flow Cytometry Human peripheral blood monocytes were stained with Mouse Anti-Human LILRA6/CD85b APC-conjugated Monoclonal Antibody (Catalog # FAB8656A, filled histogram) or Mouse IgG Isotype Control Antibody (Catalog # IC002A, open histogram). View our protocol for Staining Membrane-associated Proteins.

Reconstitution Calculator

Reconstitution Calculator

The reconstitution calculator allows you to quickly calculate the volume of a reagent to reconstitute your vial. Simply enter the mass of reagent and the target concentration and the calculator will determine the rest.

=
÷

Preparation and Storage

Shipping
The product is shipped with polar packs. Upon receipt, store it immediately at the temperature recommended below.
Stability & Storage
Protect from light. Do not freeze.
  • 12 months from date of receipt, 2 to 8 °C as supplied.

Background: IgG1

R&D Systems offers a range of secondary antibodies and controls for flow cytometry, immunohistochemistry, and Western blotting. We provide species-specific secondary antibodies that are available with a variety of conjugated labels.

Our NorthernLights fluorescent secondary antibodies are bright and resistant to photobleaching. We are currently offering secondary antibodies recognizing mouse, rat, goat, sheep, and rabbit IgG as well as chicken IgY. These reagents are available with three distinct excitation and emission maxima, making them ideal for multi-color fluorescence microscopy.

Long Name
Immunoglobulin G1
Alternate Names
IgG1; Igh-4; RGD1359539; VH7183

Product Datasheets

You must select a language.

x

Citations for Mouse IgG1 APC-conjugated Antibody

R&D Systems personnel manually curate a database that contains references using R&D Systems products. The data collected includes not only links to publications in PubMed, but also provides information about sample types, species, and experimental conditions.

24 Citations: Showing 1 - 10
Filter your results:

Filter by:

  1. MET-induced CD73 restrains STING-mediated immunogenicity of EGFR-mutant lung cancer
    Authors: R Yoshida, M Saigi, T Tani, BF Springer, H Shibata, S Kitajima, NR Mahadevan, M Campisi, W Kim, Y Kobayashi, TC Thai, K Haratani, Y Yamamoto, SK Sundararam, EH Knelson, A Vajdi, I Canadas, R Uppaluri, CP Paweletz, JJ Miret, PH Lizotte, PC Gokhale, PA Janne, DA Barbie
    Cancer Research, 2022;0(0):.
    Species: Human
    Sample Types: Whole Cells
    Applications: Flow Cytometry Control
  2. Functional Downregulation of PD-L1 and PD-L2 by CpG and non-CpG Oligonucleotides in Melanoma Cells
    Authors: J Kleemann, K Steinhorst, V König, N Zöller, J Cinatl, D Özistanbul, R Kaufmann, M Meissner, S Kippenberg
    Cancers, 2022;14(19):.
    Species: Human
    Sample Types: Whole Cells
    Applications: Flow Cytometry
  3. Nobiletin and Xanthohumol Sensitize Colorectal Cancer Stem Cells to Standard Chemotherapy
    Authors: A Turdo, A Glaviano, G Pepe, F Calapà, S Raimondo, ME Fiori, D Carbone, MG Basilicata, V Di Sarno, C Ostacolo, B Parrino, S Cascioferr, C Pecoraro, S Di Franco, D Bellavia, M Gaggianesi, V Veschi, M Lo Iacono, G Ganduscio, VD Pantina, LR Mangiapane, MR Bongiorno, R Alessandro, M Todaro, R De Maria, P Diana, P Campiglia, G Stassi
    Cancers, 2021;13(16):.
    Species: Human
    Sample Types: Whole Cells
    Applications: Flow Cytometry
  4. Two 20-Residue-Long Peptides Derived from Plasmodium vivax Merozoite Surface Protein 10 EGF-Like Domains Are Involved in Binding to Human Reticulocytes
    Authors: LA Ricaurte-C, A Lovera, DA Moreno-Pér, MD Bohórquez, CF Suárez, E Gutiérrez-, L Cuy-Chapar, D Garzón-Osp, MA Patarroyo
    International Journal of Molecular Sciences, 2021;22(4):.
    Species: Human
    Sample Types: Whole Cells
    Applications: Flow Cytometry
  5. Targeting the ABC transporter ABCB5 sensitizes glioblastoma to temozolomide-induced apoptosis through a cell-cycle checkpoint regulation mechanism
    Authors: CAA Lee, P Banerjee, BJ Wilson, S Wu, Q Guo, G Berg, S Karpova, A Mishra, JW Lian, J Tran, M Emmerich, GF Murphy, MH Frank, NY Frank
    J. Biol. Chem., 2020;0(0):.
    Species: Mouse
    Sample Types: Whole Cells
    Applications: Flow Cytometry
  6. Development of an ex vivo xenogeneic bone environment producing human platelet-like cells
    Authors: S Fujiyama, N Hori, T Sato, S Enosawa, M Murata, E Kobayashi
    PLoS ONE, 2020;15(4):e0230507.
    Species: Human
    Sample Types: Whole Cells
    Applications: Flow Cytometry
  7. Impact of p53 status on TRAIL-mediated apoptotic and non-apoptotic signaling in cancer cells
    Authors: A Willms, H Schittek, S Rahn, J Sosna, U Mert, D Adam, A Trauzold
    PLoS ONE, 2019;14(4):e0214847.
    Species: Human
    Sample Types: Whole Cells
    Applications: Flow Cytometry
  8. Pro-inflammatory monocyte profile in patients with major depressive disorder and suicide behaviour and how ketamine induces anti-inflammatory M2 macrophages by NMDAR and mTOR
    Authors: W Nowak, LN Grendas, LM Sanmarco, IG Estecho, ÁR Arena, N Eberhardt, DE Rodante, MP Aoki, FM Daray, EA Carrera Si, AE Errasti
    EBioMedicine, 2019;0(0):.
    Species: Human
    Sample Types: Whole Cells
    Applications: ICC
  9. Increase in bone metabolic markers and circulating osteoblast-lineage cells after orthognathic surgery
    Authors: Y Abe, M Chiba, S Yaklai, RS Pechayco, H Suzuki, T Takahashi
    Sci Rep, 2019;9(1):20106.
    Species: Human
    Sample Types: Whole Cells
    Applications: Flow Cytometry
  10. Targeting chemoresistant colorectal cancer via systemic administration of a BMP7 variant
    Authors: V Veschi, LR Mangiapane, A Nicotra, S Di Franco, E Scavo, T Apuzzo, DS Sardina, M Fiori, A Benfante, ML Colorito, G Cocorullo, F Giuliante, C Cipolla, G Pistone, MR Bongiorno, A Rizzo, CM Tate, X Wu, S Rowlinson, LF Stancato, M Todaro, R De Maria, G Stassi
    Oncogene, 2019;0(0):.
    Species: Human
    Sample Types: Whole Cells
    Applications: ICC
  11. TRAIL Induces Nuclear Translocation and Chromatin Localization of TRAIL Death Receptors
    Authors: U Mert, A Adawy, E Scharff, P Teichmann, A Willms, V Haselmann, C Colmorgen, J Lemke, S von Karste, J Fritsch, A Trauzold
    Cancers (Basel), 2019;11(8):.
    Species: Human
    Sample Types: Whole Cells
    Applications: Flow Cytometry
  12. Induction of MET Receptor Tyrosine Kinase Down-regulation through Antibody-mediated Receptor Clustering
    Authors: W Li, A Dick, F Lu, H Zhang, H Sun
    Sci Rep, 2019;9(1):1988.
    Species: Human
    Sample Types: Whole Cells
    Applications: ICC
  13. CXCR7 expression in diffuse large B-cell lymphoma identifies a subgroup of CXCR4+ patients with good prognosis
    Authors: MJ Moreno, A Gallardo, S Novelli, A Mozos, M Aragó, MÁ Pavón, MV Céspedes, V Pallarès, A Falgàs, M Alcoceba, O Blanco, M Gonzalez-D, J Sierra, R Mangues, I Casanova
    PLoS ONE, 2018;13(6):e0198789.
    Species: Human
    Sample Types: Whole Cells
    Applications: Flow Cytometry
  14. Regeneration of the lung alveolus by an evolutionarily conserved epithelial progenitor
    Authors: WJ Zacharias, DB Frank, JA Zepp, MP Morley, FA Alkhaleel, J Kong, S Zhou, E Cantu, EE Morrisey
    Nature, 2018;555(7695):251-255.
    Species: Human
    Sample Types: Whole Cells
    Applications: Control
  15. Equine Mesenchymal Stromal Cells retain a pericyte-like phenotype
    Authors: CL Esteves, TA Sheldrake, L Dawson, T Menghini, E Rink, K Amilon, N Khan, B Peault, X Donadeu
    Stem Cells Dev., 2017;0(0):.
    Species: Equine
    Sample Types: Whole Cells
    Applications: Flow Cytometry
  16. Biological Activity of Masked Endotoxin
    Authors: H Schwarz, J Gornicec, T Neuper, MA Parigiani, M Wallner, A Duschl, J Horejs-Hoe
    Sci Rep, 2017;7(0):44750.
    Species: Human
    Sample Types: Whole Cells
    Applications: Flow Cytometry Control
  17. Differential cytokine contributions of perivascular haematopoietic stem cell niches
    Authors: N Asada, Y Kunisaki, H Pierce, Z Wang, NF Fernandez, A Birbrair, A Ma'ayan, PS Frenette
    Nat. Cell Biol, 2017;19(3):214-223.
    Species: Mouse
    Sample Types: Whole Cells
    Applications: Flow Cytometry
  18. Role of IL-18 in atopic asthma is determined by balance of IL-18/IL-18BP/IL-18R
    Authors: H Zhang, J Wang, L Wang, H Xie, L Chen, S He
    J. Cell. Mol. Med., 2017;0(0):.
    Applications: Flow Cytometry Control
  19. Signaling via PI3K/FOXO1A pathway modulates formation and survival of human embryonic stem cell-derived endothelial cells.
    Authors: Merkely B, Gara E, Lendvai Z, Skopal J, Leja T, Zhou W, Kosztin A, Varady G, Mioulane M, Bagyura Z, Nemeth T, Harding S, Foldes G
    Stem Cells Dev, 2015;24(7):869-78.
    Species: Human
    Sample Types: Whole Cells
    Applications: Flow Cytometry
  20. Prerequisites for Functional Interleukin 31 Signaling and Its Feedback Regulation by Suppressor of Cytokine Signaling 3 (SOCS3).
    Authors: Maier E, Mittermeir M, Ess S, Neuper T, Schmiedlechner A, Duschl A, Horejs-Hoeck J
    J Biol Chem, 2015;290(41):24747-59.
    Species: Human
    Sample Types: Whole Cells
    Applications: Flow Cytometry
  21. Cancer stem-like sphere cells induced from de-differentiated hepatocellular carcinoma-derived cell lines possess the resistance to anti-cancer drugs.
    Authors: Hashimoto, Noriaki, Tsunedomi, Ryouichi, Yoshimura, Kiyoshi, Watanabe, Yusaku, Hazama, Shoichi, Oka, Masaaki
    BMC Cancer, 2014;14(0):722.
    Species: Human
    Sample Types: Whole Cells
    Applications: Flow Cytometry Control
  22. The Spiegelmer NOX-A12, a novel CXCL12 inhibitor, interferes with chronic lymphocytic leukemia cell motility and causes chemosensitization.
    Authors: Hoellenriegel J, Zboralski D, Maasch C, Rosin N, Wierda W, Keating M, Kruschinski A, Burger J
    Blood, 2014;123(7):1032-9.
    Species: Mouse
    Sample Types: Whole Cells
    Applications: Flow Cytometry
  23. VEGFR2 expressing circulating (progenitor) cell populations in volunteers and cancer patients.
    Authors: Vroling L, Yuana Y, Schuurhuis GJ, van Hinsbergh VW, Gundy C, de Haas R, van Cruijsen H, Boven E, Hoekman K, Broxterman HJ
    Thromb. Haemost., 2007;98(2):440-50.
    Species: Human
    Sample Types: Whole Blood
    Applications: Control
  24. Transforming growth factor-alpha: a major human serum factor that promotes human keratinocyte migration.
    Authors: Li Y, Fan J, Chen M, Li W, Woodley DT
    J. Invest. Dermatol., 2006;126(9):2096-105.
    Species: Human
    Sample Types: Serum
    Applications: Control

FAQs

No product specific FAQs exist for this product, however you may

View all Isotype Control FAQs

Reviews for Mouse IgG1 APC-conjugated Antibody

Average Rating: 4.3 (Based on 3 Reviews)

5 Star
33.33%
4 Star
66.67%
3 Star
0%
2 Star
0%
1 Star
0%

Have you used Mouse IgG1 APC-conjugated Antibody?

Submit a review and receive an Amazon gift card.

$25/€18/£15/$25CAN/¥75 Yuan/¥1250 Yen for a review with an image

$10/€7/£6/$10 CAD/¥70 Yuan/¥1110 Yen for a review without an image

Submit a Review

Filter by:


Mouse IgG1 APC-conjugated Antibody
By Abby Sukarto on 02/14/2020
Application: Flow Sample Tested: Bone Extracts Species: Human

Mouse IgG1 APC-conjugated Antibody
By Anonymous on 09/10/2016
Application: Flow Sample Tested: ASTROCYTE Species: Human

Mouse IgG1 APC-conjugated Antibody
By Anonymous on 06/15/2016
Application: Flow Sample Tested: Human embryonic stem cells derived mesoderm (H1) Species: Human

1 million of H1 embryonic stem cells were incubated with 10ul of mouse IgG1 APC-conjugated and 10 ul of mouse IgG1 PE-conjugated Antibodies for 45min at 4C in dark. Cells were analyzed user the LSRII analyzer.