Anti- Solanezumab (Anti-Idiotype) Antibody
R&D Systems | Catalog # MAB10124
Key Product Details
Species Reactivity
Applications
Label
Antibody Source
Product Specifications
Immunogen
Specificity
Clonality
Host
Isotype
Scientific Data Images for Anti- Solanezumab (Anti-Idiotype) Antibody
Detection of Solanezumab by Western Blot.
Western blot shows Solanexumab, Trastuzumab (negative control), and Adalibumab (negative control). PVDF membrane was probed with 1 µg/mL of Rabbit Anti-Anti- Solanezumab (Anti-Idiotype) Monoclonal Antibody (Catalog # MAB10124) followed by HRP-conjugated Anti-Rabbit IgG Secondary Antibody (Catalog # HAF008). A specific band was detected for Solanezumab at approximately 240 kDa (as indicated). Human IgG is shown as a loading control. This experiment was conducted under non-reducing conditions and using Immunoblot Buffer Group 1.Detection of Anti-APP (Solanezumab) on Human PBMC by flow cytometry.
Human PBMC were stained with Human anti-Human APP (Solanezumab) Monoclonal Antibody (Catalog # MAB9919), then either (A) Rabbit Anti-Solanezumab (Anti-Idiotype) (Catalog # MAB10124) or (B) normal rabbit IgG (Catalog # MAB1050) followed by APC-conjugated anti-rabbit IgG secondary antibody (Catalog # F0111) and Mouse anti-Human CD14 PE-conjugated Monoclonal Antibody (Catalog # FAB3832P).Applications for Anti- Solanezumab (Anti-Idiotype) Antibody
CyTOF-ready
Flow Cytometry
Sample: Human PBMCs stained with Human anti-Human APP (Solanezumab), Catalog # MAB9919
Western Blot
Sample: Solanezumab
Under non-reducing conditions only
Flow Cytometry Panel Builder
Bio-Techne Knows Flow Cytometry
Save time and reduce costly mistakes by quickly finding compatible reagents using the Panel Builder Tool.
Advanced Features
- Spectra Viewer - Custom analysis of spectra from multiple fluorochromes
- Spillover Popups - Visualize the spectra of individual fluorochromes
- Antigen Density Selector - Match fluorochrome brightness with antigen density
Formulation, Preparation, and Storage
Purification
Reconstitution
Reconstitute at 0.5 mg/mL in sterile PBS. For liquid material, refer to CoA for concentration.
Formulation
Shipping
Stability & Storage
- 12 months from date of receipt, -20 to -70 °C as supplied.
- 1 month, 2 to 8 °C under sterile conditions after reconstitution.
- 6 months, -20 to -70 °C under sterile conditions after reconstitution.
Calculators
Background: Solanezumab
Additional Solanezumab Products
Product Documents for Anti- Solanezumab (Anti-Idiotype) Antibody
Certificate of Analysis
To download a Certificate of Analysis, please enter a lot or batch number in the search box below.
Note: Certificate of Analysis not available for kit components.
Product Specific Notices for Anti- Solanezumab (Anti-Idiotype) Antibody
For research use only
Customer Reviews for Anti- Solanezumab (Anti-Idiotype) Antibody
There are currently no reviews for this product. Be the first to review Anti- Solanezumab (Anti-Idiotype) Antibody and earn rewards!
Have you used Anti- Solanezumab (Anti-Idiotype) Antibody?
Submit a review and receive an Amazon gift card!
$25/€18/£15/$25CAN/¥2500 Yen for a review with an image
$10/€7/£6/$10CAN/¥1110 Yen for a review without an image
Submit a review
Protocols
Find general support by application which include: protocols, troubleshooting, illustrated assays, videos and webinars.
- 7-Amino Actinomycin D (7-AAD) Cell Viability Flow Cytometry Protocol
- Cellular Response to Hypoxia Protocols
- Extracellular Membrane Flow Cytometry Protocol
- Flow Cytometry Protocol for Cell Surface Markers
- Flow Cytometry Protocol for Staining Membrane Associated Proteins
- Flow Cytometry Staining Protocols
- Flow Cytometry Troubleshooting Guide
- Intracellular Flow Cytometry Protocol Using Alcohol (Methanol)
- Intracellular Flow Cytometry Protocol Using Detergents
- Intracellular Nuclear Staining Flow Cytometry Protocol Using Detergents
- Intracellular Staining Flow Cytometry Protocol Using Alcohol Permeabilization
- Intracellular Staining Flow Cytometry Protocol Using Detergents to Permeabilize Cells
- Propidium Iodide Cell Viability Flow Cytometry Protocol
- Protocol for Liperfluo
- Protocol for the Characterization of Human Th22 Cells
- Protocol for the Characterization of Human Th9 Cells
- Protocol: Annexin V and PI Staining by Flow Cytometry
- Protocol: Annexin V and PI Staining for Apoptosis by Flow Cytometry
- R&D Systems Quality Control Western Blot Protocol
- Troubleshooting Guide: Fluorokine Flow Cytometry Kits
- Troubleshooting Guide: Western Blot Figures
- Western Blot Conditions
- Western Blot Protocol
- Western Blot Protocol for Cell Lysates
- Western Blot Troubleshooting
- Western Blot Troubleshooting Guide
- View all Protocols, Troubleshooting, Illustrated assays and Webinars
FAQs for Anti- Solanezumab (Anti-Idiotype) Antibody
-
Q: What is an anti-idiotype antibody?
A: An anti-idiotype antibody is specific for the unique variable (antigen binding) region of another antibody. We have anti-idiotype antibodies to commecially available therapeutic antibodies or biosimilars.