BMAL1 Antibody (OTI1C11) [Alexa Fluor™ Plus 488]

Novus Biologicals | Catalog # NBP2-70207AFP488

Novus Biologicals
Loading...

Key Product Details

Species Reactivity

Human, Mouse, Rat

Applications

Immunohistochemistry, Immunohistochemistry-Paraffin, Western Blot, Immunocytochemistry/ Immunofluorescence

Label

Alexa Fluor Plus 488

Antibody Source

Monoclonal Mouse IgG1 Clone # OTI1C11
Loading...

Product Specifications

Immunogen

Full length human recombinant protein of human ARNTL(NP_001169) produced in HEK293T cell.

Reactivity Notes

Please note that this antibody is reactive to Mouse and derived from the same host, Mouse. Mouse-On-Mouse blocking reagent may be needed for IHC and ICC experiments to reduce high background signal. You can find these reagents under catalog numbers PK-2200-NB and MP-2400-NB. Please contact Technical Support if you have any questions.

Clonality

Monoclonal

Host

Mouse

Isotype

IgG1

Applications for BMAL1 Antibody (OTI1C11) [Alexa Fluor™ Plus 488]

Application
Recommended Usage

Immunocytochemistry/ Immunofluorescence

Optimal dilutions of this antibody should be experimentally determined.

Immunohistochemistry

Optimal dilutions of this antibody should be experimentally determined.

Immunohistochemistry-Paraffin

Optimal dilutions of this antibody should be experimentally determined.

Western Blot

Optimal dilutions of this antibody should be experimentally determined.
Application Notes
Optimal dilution of this antibody should be experimentally determined.

Formulation, Preparation, and Storage

Purification

Immunogen affinity purified

Formulation

50mM Sodium Borate

Preservative

0.05% Sodium Azide

Concentration

Please see the vial label for concentration. If unlisted please contact technical services.

Shipping

The product is shipped with polar packs. Upon receipt, store it immediately at the temperature recommended below.

Stability & Storage

Store at 4C in the dark.

Background: BMAL1

Aryl hydrocarbon receptor nuclear translocator-like (ARNTL), also known as Bmal1 or Mop3 is a major component of the circadian clock oscillator. Specifically, BMAL-1 acts as a general dimerization partner for a subset of the bHLH-PAS (basic-helix-loop-helix-PER-ARNT-SIM) superfamily of transcription regulators, is involved in circadian rhythm generation. BMAL 1 interacts with MOP4, CLOCK, Hypoxia-inducible factor-1 alpha and -2 alpha. This interaction appears to be distinct from that of the more characterized general partner, ARNT (HIF-1Beta).

BMAL1 is highly expressed in the adult brain, skeletal muscle and heart, and has been associated with hypertension and type 2 diabetes. Because of its role in the circadian clock oscillator, BMAL-1 is also thought to be invloven seasonal affective disorder. Therefore, BMAL1 antibodies are useful for circadian studies as well as heart and brain research.

Long Name

Brain and Muscle ARNT-Like 1

Alternate Names

ARNTL, BHLHE5, BMAL1c, JAP3, MOP3, PASD3, TIC

Gene Symbol

BMAL1

Additional BMAL1 Products

Product Documents for BMAL1 Antibody (OTI1C11) [Alexa Fluor™ Plus 488]

Certificate of Analysis

To download a Certificate of Analysis, please enter a lot or batch number in the search box below.

Product Specific Notices for BMAL1 Antibody (OTI1C11) [Alexa Fluor™ Plus 488]



This product is provided under an intellectual property license from Life Technologies Corporation. The transfer of this product is conditioned on the buyer using the purchased product solely in research conducted by the buyer, excluding contract research or any fee for service research, and the buyer must not (1) use this product or its components for (a) diagnostic, therapeutic or prophylactic purposes; (b) testing, analysis or screening services, or information in return for compensation on a per-test basis; or (c) manufacturing or quality assurance or quality control, and/or (2) sell or transfer this product or its components for resale, whether or not resold for use in research. For information on purchasing a license to this product for purposes other than as described above, contact Life Technologies Corporation, 5781 Van Allen Way, Carlsbad, CA 92008 USA or outlicensing@thermofisher.com. This conjugate is made on demand. Actual recovery may vary from the stated volume of this product. The volume will be greater than or equal to the unit size stated on the datasheet.

This product is for research use only and is not approved for use in humans or in clinical diagnosis. Primary Antibodies are guaranteed for 1 year from date of receipt.

Customer Reviews for BMAL1 Antibody (OTI1C11) [Alexa Fluor™ Plus 488]

There are currently no reviews for this product. Be the first to review BMAL1 Antibody (OTI1C11) [Alexa Fluor™ Plus 488] and earn rewards!

Have you used BMAL1 Antibody (OTI1C11) [Alexa Fluor™ Plus 488]?

Submit a review and receive an Amazon gift card!

$25/€18/£15/$25CAN/¥2500 Yen for a review with an image

$10/€7/£6/$10CAN/¥1110 Yen for a review without an image

Submit a review
Amazon Gift Card

Protocols

Find general support by application which include: protocols, troubleshooting, illustrated assays, videos and webinars.

FAQs

No product specific FAQs exist for this product.

View all FAQs for Antibodies
Loading...