Human Oct-4A Antibody (653108)
R&D Systems | Catalog # MAB17591
Scientific images may be resized, cropped, or adjusted for brightness or contrast for presentation purposes. These updates are limited to presentation and do not affect the underlying scientific interpretation of the data. Where available, additional source data may be provided upon request.
Key Product Details
Species Reactivity
Validated:
Cited:
Applications
Validated:
Cited:
Label
Antibody Source
Product Specifications
Immunogen
Met1-Glu135
Accession # NP_002692
Specificity
Clonality
Host
Isotype
Scientific Data Images for Human Oct-4A Antibody (653108)
Detection of Oct‑4A in NTERA-2 cells by Flow Cytometry
NTERA-2 cells were stained with Mouse Anti-Human Oct‑4A Monoclonal Antibody (Catalog # MAB17591, filled histogram) or isotype control antibody (Catalog # MAB003, open histogram) followed by Allophycocyanin-conjugated Anti-Mouse IgG Secondary Antibody (Catalog # F0101B). To facilitate intracellular staining, cells were fixed and permeabilized with FlowX FoxP3 Fixation & Permeabilization Buffer Kit (Catalog # FC012). View our protocol for Staining Intracellular Molecules.Detection of Human Oct‑4A by Western Blot.
Western blot shows lysates of HeLa human cervical epithelial carcinoma cell line and NTera-2 human testicular embryonic carcinoma cell line. PVDF Membrane was probed with 0.5 µg/mL of Mouse Anti-Human Oct-4A Monoclonal Antibody (Catalog # MAB17591) followed by HRP-conjugated Anti-Mouse IgG Secondary Antibody (HAF007). A specific band was detected for Oct-4A at approximately 50 kDa (as indicated). This experiment was conducted under reducing conditions and using Immunoblot Buffer Group 1.Oct-4A and E-Cadherin in BG01V Human Stem Cells.
Oct-4A and E-Cadherin were detected in human BG01V embryonic stem cells grown on irradiated MEF cells using 10 µg/mL Human Oct-4A Monoclonal Antibody (Catalog # MAB17591) and 10 µg/mL Human E-Cadherin Affinity-purified Polyclonal Antibody (AF648). Cells were incubated with primary antibodies for 3 hours at room temperature. Cells were stained for Oct-4A using the Northern-Lights™ 493-conjugated Anti-Mouse IgG Secondary Antibody (green; NL009), and stained for E-Cadherin using the Northern-Lights™ 557-conjugated Anti-Goat IgG Secondary Antibody (red; NL001). Specific staining of Oct-4A was localized to nuclei. View our protocol for Fluorescent ICC Staining of Cells on Coverslips.Detection of Oct‑4A in BG01V Human Stem Cells by Flow Cytometry.
BG01V human embryonic stem cells were stained with Human Oct-4A Monoclonal Antibody (Catalog # MAB17591, filled histogram) or isotype control antibody (MAB003, open histogram), followed by Allophycocyanin-conjugated Anti-Mouse IgG F(ab')2Secondary Antibody (F0101B). To facilitate intracellular staining, cells were fixed with paraformaldehyde and permeabilized with saponin.Detection of Oct‑4A in iPSCs by Flow Cytometry.
iPSCs were stained with Mouse Anti-Human Oct‑4A Monoclonal Antibody (Catalog # MAB17591, filled histogram) or isotype control antibody (Catalog # MAB003, open histogram), followed by Allophycocyanin-conjugated Anti-Mouse IgG Secondary Antibody (Catalog # F0101B). To facilitate intracellular staining, cells were fixed with Flow Cytometry Fixation Buffer (Catalog # FC004) and permeabilized with Flow Cytometry Permeabilization/Wash Buffer I (Catalog # FC005). View our protocol for Staining Intracellular Molecules.Applications for Human Oct-4A Antibody (653108)
CyTOF-ready
Immunocytochemistry
Sample: Immersion fixed BG01V human embryonic stem cells and immersion fixed ADLF1 and FAB2 induced pluripotent stem cell lines
Intracellular Staining by Flow Cytometry
Sample: NTERA-2 human testicular embryonic carcinoma cell line or BG01V human embryonic stem cells or iPSCs fixed with paraformaldehyde and permeabilized with saponin
Western Blot
Sample: HeLa human cervical epithelial carcinoma cell line and NTera‑2 human testicular embryonic carcinoma cell line
Reviewed Applications
Read 2 reviews rated 4 using MAB17591 in the following applications:
Flow Cytometry Panel Builder
Bio-Techne Knows Flow Cytometry
Save time and reduce costly mistakes by quickly finding compatible reagents using the Panel Builder Tool.
Advanced Features
- Spectra Viewer - Custom analysis of spectra from multiple fluorochromes
- Spillover Popups - Visualize the spectra of individual fluorochromes
- Antigen Density Selector - Match fluorochrome brightness with antigen density
Formulation, Preparation, and Storage
Purification
Reconstitution
Sterile PBS to a final concentration of 0.5 mg/mL. For liquid material, refer to CoA for concentration.
Formulation
Shipping
Stability & Storage
- 12 months from date of receipt, -20 to -70 °C as supplied.
- 1 month, 2 to 8 °C under sterile conditions after reconstitution.
- 6 months, -20 to -70 °C under sterile conditions after reconstitution.
Calculators
Background: Oct-4A
Long Name
Alternate Names
Gene Symbol
UniProt
Additional Oct-4A Products
Product Documents for Human Oct-4A Antibody (653108)
Certificate of Analysis
To download a Certificate of Analysis, please enter a lot or batch number in the search box below.
Note: Certificate of Analysis not available for kit components.
Product Specific Notices for Human Oct-4A Antibody (653108)
For research use only
Citations for Human Oct-4A Antibody (653108)
Customer Reviews for Human Oct-4A Antibody (653108) (2)
Have you used Human Oct-4A Antibody (653108)?
Submit a review and receive an Amazon gift card!
$25/€18/£15/$25CAN/¥2500 for a review with an image
$10/€7/£6/$10CAN/¥1110 for a review without an image
Submit a review
Customer Images
-
Application: Western BlotSample Tested: NTera-2 human testicular embryonic carcinoma cell lineSpecies: HumanVerified Customer | Posted 03/12/2022
-
Application: Immunocytochemistry/ImmunofluorescenceSample Tested: WS-1 human fetal skin fibroblast cell lineSpecies: HumanVerified Customer | Posted 01/31/2019
There are no reviews that match your criteria.
Protocols
Find general support by application which include: protocols, troubleshooting, illustrated assays, videos and webinars.
- 7-Amino Actinomycin D (7-AAD) Cell Viability Flow Cytometry Protocol
- Appropriate Fixation of IHC/ICC Samples
- Cellular Response to Hypoxia Protocols
- ClariTSA™ Fluorophore Kits
- Detection & Visualization of Antibody Binding
- Extracellular Membrane Flow Cytometry Protocol
- Flow Cytometry Protocol for Cell Surface Markers
- Flow Cytometry Protocol for Staining Membrane Associated Proteins
- Flow Cytometry Staining Protocols
- Flow Cytometry Troubleshooting Guide
- ICC Cell Smear Protocol for Suspension Cells
- ICC Immunocytochemistry Protocol Videos
- ICC for Adherent Cells
- Immunocytochemistry (ICC) Protocol
- Immunocytochemistry Troubleshooting
- Immunofluorescence of Organoids Embedded in Cultrex Basement Membrane Extract
- Immunohistochemistry (IHC) and Immunocytochemistry (ICC) Protocols
- Intracellular Flow Cytometry Protocol Using Alcohol (Methanol)
- Intracellular Flow Cytometry Protocol Using Detergents
- Intracellular Nuclear Staining Flow Cytometry Protocol Using Detergents
- Intracellular Staining Flow Cytometry Protocol Using Alcohol Permeabilization
- Intracellular Staining Flow Cytometry Protocol Using Detergents to Permeabilize Cells
- Preparing Samples for IHC/ICC Experiments
- Preventing Non-Specific Staining (Non-Specific Binding)
- Primary Antibody Selection & Optimization
- Propidium Iodide Cell Viability Flow Cytometry Protocol
- Protocol for Liperfluo
- Protocol for VisUCyte™ HRP Polymer Detection Reagent
- Protocol for the Characterization of Human Th22 Cells
- Protocol for the Characterization of Human Th9 Cells
- Protocol for the Fluorescent ICC Staining of Cell Smears - Graphic
- Protocol for the Fluorescent ICC Staining of Cultured Cells on Coverslips - Graphic
- Protocol for the Preparation and Fluorescent ICC Staining of Cells on Coverslips
- Protocol for the Preparation and Fluorescent ICC Staining of Non-adherent Cells
- Protocol for the Preparation and Fluorescent ICC Staining of Stem Cells on Coverslips
- Protocol for the Preparation of a Cell Smear for Non-adherent Cell ICC - Graphic
- Protocol: Annexin V and PI Staining by Flow Cytometry
- Protocol: Annexin V and PI Staining for Apoptosis by Flow Cytometry
- R&D Systems Quality Control Western Blot Protocol
- TUNEL and Active Caspase-3 Detection by IHC/ICC Protocol
- The Importance of IHC/ICC Controls
- Troubleshooting Guide: Fluorokine Flow Cytometry Kits
- Troubleshooting Guide: Western Blot Figures
- Western Blot Conditions
- Western Blot Protocol
- Western Blot Protocol for Cell Lysates
- Western Blot Troubleshooting
- Western Blot Troubleshooting Guide
- View all Protocols, Troubleshooting, Illustrated assays and Webinars