CD19 Antibody (CB19) - BSA Free
Novus Biologicals | Catalog # NBP2-25196
Key Product Details
Species Reactivity
Validated:
Human, Mouse
Cited:
Human, Mouse
Applications
Validated:
Western Blot, Flow Cytometry, Immunocytochemistry/ Immunofluorescence, In vitro assay, CyTOF-ready
Cited:
Western Blot, Flow Cytometry, Immunocytochemistry/ Immunofluorescence, In vitro assay
Label
Unconjugated
Antibody Source
Monoclonal Mouse IgG1 Clone # CB19
Format
BSA Free
Loading...
Product Specifications
Immunogen
Intact normal human B cell cells were used as immunogen to generate the CB19 clone.
Epitope
The exact CD19 epitope recognized by the antibody has not been mapped and is unknown.
Reactivity Notes
Mouse reactivity reported in scientific literature (PMID: 27532872).
Clonality
Monoclonal
Host
Mouse
Isotype
IgG1
Description
Novus Biologicals Mouse CD19 Antibody (CB19) - BSA Free (NBP2-25196) is a monoclonal antibody validated for use in WB, Flow and ICC/IF. Anti-CD19 Antibody: Cited in 11 publications. All Novus Biologicals antibodies are covered by our 100% guarantee.
Scientific Data Images for CD19 Antibody (CB19) - BSA Free
Immunocytochemistry/ Immunofluorescence: CD19 Antibody (CB19) - BSA Free [NBP2-25196]
Immunocytochemistry/Immunofluorescence: CD19 Antibody (CB19) [NBP2-25196] - CD19 antibody (CB19) was tested in Non-Hodgkin's lymphoma cells at 1:200 dilution. Green: Alexa Flour 488. Image from verified customer review.Flow Cytometry: CD19 Antibody (CB19) - BSA Free [NBP2-25196]
Flow Cytometry: CD19 Antibody (CB19) [NBP2-25196] - A surface stain was performed on Ramos cells with CD19 Antibody (CB19) NBP2-26646 (blue) and a matched isotype control (orange). Cells were incubated in an antibody dilution of 2.5 ug/mL for 20 minutes at room temperature. Both antibodies were conjugated to phycoerythrin.Immunocytochemistry/ Immunofluorescence: CD19 Antibody (CB19) - BSA Free [NBP2-25196]
Immunocytochemistry/Immunofluorescence: CD19 Antibody (CB19) [NBP2-25196] - The CD19 (CB19) antibody was tested in Daudi cells at a 1:40 dilution against Dylight 488 (Green). Actin and nuclei were counterstained against Phalloidin 568 (Red) and DAPI (Blue), respectively.Flow Cytometry: CD19 Antibody (CB19) - BSA Free [NBP2-25196]
Flow Cytometry: CD19 Antibody (CB19) [NBP2-25196] - Surface staining of 10^6 human lymphocytes using 0.2 ug of CD19 antibody (red) and isotype control (green). Cell surface staining kit was used for this test.Flow Cytometry: CD19 Antibody (CB19) - BSA Free [NBP2-25196]
Flow Cytometry: CD19 Antibody (CB19) [NBP2-25196] - Analysis using the FITC conjugate of NBP2-25196. Staining of CD19 in 10^6 human lymphocytes using 10 ul (0.25 ug) of this antibody. Shaded histogram represents cells without antibody; green represents isotype control ; red represents anti-CD19 antibody.Flow Cytometry: CD19 Antibody (CB19) - BSA Free [NBP2-25196]
Flow Cytometry: CD19 Antibody (CB19) [NBP2-25196] - Analysis using the PE conjugate of NBP2-25196. Staining of CD19 in 1x10^6 human PBMC using 10 ul (0.25 ug) of was used to test this product. Propidium iodide negative lymphocyte population gated for analysis.Flow Cytometry: CD19 Antibody (CB19) - BSA Free [NBP2-25196]
Flow Cytometry: CD19 Antibody (CB19) [NBP2-25196] - Analysis using the Alexa Fluor (R) 700 conjugate of NBP2-25196. Staining of human PBMC. Image from verified customer review.Flow Cytometry: CD19 Antibody (CB19) - BSA Free [NBP2-25196]
Flow Cytometry: CD19 Antibody (CB19) [NBP2-25196] - Analysis using the DyLight 405 conjugate of NBP2-25196. Staining of CD19 in human PBMCs using anti-CD19 antibody. Image from verified customer review.Flow Cytometry: CD19 Antibody (CB19) - BSA Free [NBP2-25196]
Flow Cytometry: CD19 Antibody (CB19) [NBP2-25196] - A surface stain was performed on human peripheral blood lymphocytes with TACI/TNFRSF13B/CVID (1A1) antibody NB600-1189PE and a matched isotype control. Cells were incubated in an antibody dilution of 2 ug/mL for 20 minutes at room temperature. A co-stain was performed with NBP2-25196AF647.Flow Cytometry: CD19 Antibody (CB19) - BSA Free [NBP2-25196]
Flow Cytometry: CD19 Antibody (CB19) [NBP2-25196] - A surface stain was performed on human peripheral blood lymphocytes with CD9 (HI9a) antibody NB100-77915AF647 and a matched isotype control NBP2-27287AF488. Cells were incubated in an antibody dilution of 1 ug/mL for 20 minutes at room temperature. A co-stain was performed with NBP2-26646.Applications for CD19 Antibody (CB19) - BSA Free
Application
Recommended Usage
Flow Cytometry
0.2 ug/10^6 cells
Immunocytochemistry/ Immunofluorescence
1:25-1:100
In vitro assay
reported in scientific literature (PMID 9576485)
Western Blot
reported in scientific literature (PMID 17327405)
Application Notes
This antibody is CyTOF ready.
Reviewed Applications
Read 1 review rated 5 using NBP2-25196 in the following applications:
Flow Cytometry Panel Builder
Bio-Techne Knows Flow Cytometry
Save time and reduce costly mistakes by quickly finding compatible reagents using the Panel Builder Tool.
Advanced Features
- Spectra Viewer - Custom analysis of spectra from multiple fluorochromes
- Spillover Popups - Visualize the spectra of individual fluorochromes
- Antigen Density Selector - Match fluorochrome brightness with antigen density
Formulation, Preparation, and Storage
Purification
Protein G purified
Formulation
PBS
Format
BSA Free
Preservative
0.02% Sodium Azide
Concentration
1.0 mg/ml
Shipping
The product is shipped with polar packs. Upon receipt, store it immediately at the temperature recommended below.
Stability & Storage
Store at 4C short term. Aliquot and store at -20C long term. Avoid freeze-thaw cycles.
Background: CD19
Considering the role of CD19 in BCR signaling and its expression in development from pre-B cells through plasma cells, it is understandable that CD19 dysfunction and abnormal expression is associated with numerous B cell malignancies and autoimmune disorders (1-5). CD19 expression is typically observed at relatively normal levels in B cell acute lymphoblastic leukemia (B-ALL) and chronic lymphoblastic leukemia (CLL) but is often reduced other types of lymphoma including diffuse large B cell lymphoma (DLBCL) and follicular lymphoma (FL) (1,2). On the other hand, CD19 expression is typically increased in autoimmune disorders such as systemic sclerosis (SSc) and multiple sclerosis (MS) as modeled by experimental autoimmune encephalomyelitis (EAE) (2). CD19 has become a therapeutic molecular target for the treatment of B cell lymphomas and autoimmune disorders using monoclonal antibodies (mAbs), bi-specific T cell engaging (BiTE) antibodies, and CD19-specific chimeric antigen receptor (CAR) T cells (1,2,4-6). Although anti-CD19 CAR T cell therapy has become the standard for the treatment of B cell malignancies, patients may experience relapse due to resistance mechanisms (6). Strategies to improve efficacy and limit relapse include combination of CAR T cell therapy with immune checkpoint inhibitors like anti-PD-1 (4,6).
References
1. Wang K, Wei G, Liu D. CD19: a biomarker for B cell development, lymphoma diagnosis and therapy. Exp Hematol Oncol. 2012;1(1):36. https://doi.org/10.1186/2162-3619-1-36
2. Li X, Ding Y, Zi M, et al. CD19, from bench to bedside. Immunol Lett. 2017;183:86-95. https://doi.org/10.1016/j.imlet.2017.01.010
3. Wentink MWJ, van Zelm MC, van Dongen JJM, Warnatz K, van der Burg M. Deficiencies in the CD19 complex. Clin Immunol. 2018;195:82-87. https://doi.org/10.1016/j.clim.2018.07.017
4. Frigault MJ, Maus MV. State of the art in CAR T cell therapy for CD19+ B cell malignancies. J Clin Invest. 2020;130(4):1586-1594. https://doi.org/10.1172/JCI129208
5. Penack O, Koenecke C. Complications after CD19+ CAR T-Cell Therapy. Cancers (Basel). 2020;12(11):3445. https://doi.org/10.3390/cancers12113445
6. Bouziana S, Bouzianas D. Anti-CD19 CAR-T cells: Digging in the dark side of the golden therapy. Crit Rev Oncol Hematol. 2021;157:103096. https://doi.org/10.1016/j.critrevonc.2020.103096
Additional CD19 Products
Product Documents for CD19 Antibody (CB19) - BSA Free
Product Specific Notices for CD19 Antibody (CB19) - BSA Free
This product is for research use only and is not approved for use in humans or in clinical diagnosis. Primary Antibodies are guaranteed for 1 year from date of receipt.
Related Research Areas
Citations for CD19 Antibody (CB19) - BSA Free
Customer Reviews for CD19 Antibody (CB19) - BSA Free (1)
5 out of 5
1 Customer Rating
Have you used CD19 Antibody (CB19) - BSA Free?
Submit a review and receive an Amazon gift card!
$25/€18/£15/$25CAN/¥2500 Yen for a review with an image
$10/€7/£6/$10CAN/¥1110 Yen for a review without an image
Submit a review
Customer Images
Showing
1
-
1 of
1 review
Showing All
Filter By:
-
Application: ImmunocytochemistrySample Tested: Non-Hodgkin's lymphoma cellsSpecies: HumanVerified Customer | Posted 12/15/2021Non-Hodgkin's lymphoma cells 1ry antibody dilution 1:200 2ry antibody 1:400 Dye Alexa Fluor 488
There are no reviews that match your criteria.
Protocols
Find general support by application which include: protocols, troubleshooting, illustrated assays, videos and webinars.
- 7-Amino Actinomycin D (7-AAD) Cell Viability Flow Cytometry Protocol
- Appropriate Fixation of IHC/ICC Samples
- Cellular Response to Hypoxia Protocols
- Detection & Visualization of Antibody Binding
- Extracellular Membrane Flow Cytometry Protocol
- Flow Cytometry Protocol for Cell Surface Markers
- Flow Cytometry Protocol for Staining Membrane Associated Proteins
- Flow Cytometry Staining Protocols
- Flow Cytometry Troubleshooting Guide
- ICC Cell Smear Protocol for Suspension Cells
- ICC Immunocytochemistry Protocol Videos
- ICC for Adherent Cells
- Immunocytochemistry (ICC) Protocol
- Immunocytochemistry Troubleshooting
- Immunofluorescence of Organoids Embedded in Cultrex Basement Membrane Extract
- Immunohistochemistry (IHC) and Immunocytochemistry (ICC) Protocols
- Intracellular Flow Cytometry Protocol Using Alcohol (Methanol)
- Intracellular Flow Cytometry Protocol Using Detergents
- Intracellular Nuclear Staining Flow Cytometry Protocol Using Detergents
- Intracellular Staining Flow Cytometry Protocol Using Alcohol Permeabilization
- Intracellular Staining Flow Cytometry Protocol Using Detergents to Permeabilize Cells
- Preparing Samples for IHC/ICC Experiments
- Preventing Non-Specific Staining (Non-Specific Binding)
- Primary Antibody Selection & Optimization
- Propidium Iodide Cell Viability Flow Cytometry Protocol
- Protocol for VisUCyte™ HRP Polymer Detection Reagent
- Protocol for the Characterization of Human Th22 Cells
- Protocol for the Characterization of Human Th9 Cells
- Protocol for the Fluorescent ICC Staining of Cell Smears - Graphic
- Protocol for the Fluorescent ICC Staining of Cultured Cells on Coverslips - Graphic
- Protocol for the Preparation and Fluorescent ICC Staining of Cells on Coverslips
- Protocol for the Preparation and Fluorescent ICC Staining of Non-adherent Cells
- Protocol for the Preparation and Fluorescent ICC Staining of Stem Cells on Coverslips
- Protocol for the Preparation of a Cell Smear for Non-adherent Cell ICC - Graphic
- Protocol: Annexin V and PI Staining by Flow Cytometry
- Protocol: Annexin V and PI Staining for Apoptosis by Flow Cytometry
- R&D Systems Quality Control Western Blot Protocol
- TUNEL and Active Caspase-3 Detection by IHC/ICC Protocol
- The Importance of IHC/ICC Controls
- Troubleshooting Guide: Fluorokine Flow Cytometry Kits
- Troubleshooting Guide: Western Blot Figures
- Western Blot Conditions
- Western Blot Protocol
- Western Blot Protocol for Cell Lysates
- Western Blot Troubleshooting
- Western Blot Troubleshooting Guide