Stem Cell Factor Receptor (CD117, the gene product of the c-kit proto-oncogene) and its ligand, Stem Cell Factor (SCF), also known as c-kit Ligand, Mast Cell Growth Factor, play essential roles in gametogenesis, melanogenesis, and hematopoiesis. The human SCF Receptor cDNA encodes a 972 amino acid (aa) residue precursor membrane protein with a 25 aa residue signal peptide (experimentally determined), a 495 aa residue extracellular domain, a 23 aa residue transmembrane segment, and a 429 aa residue cytoplasmic domain. SCF Receptor is a member of the type III subfamily of Receptor Tyrosine Kinases (RTK) that also includes the receptors for M-CSF, Flt-3, PDGF, and VEGF. All class III RTKs are characterized by the presence of five immunoglobulin-like domains in their extracellular region and a split kinase domain in their intracellular region. SCF binding induces receptor homodimerization and signal transduction. SCF Receptor is expressed in hematopoietic progenitor cells, normal B and T lymphocyte progenitor cells, mast cells, germ cells, melanocytes, neurons, glial cells, placenta, kidney, lung, and gut. In addition, SCF Receptor expression has also been reported in a number of human tumor cell lines. SCF Receptor can be proteolytically cleaved from the cell surface and high levels of soluble SCF Receptor has been detected in cell conditioned medium and human plasma. Recombinant soluble SCF Receptor binds SCF with high affinity and is a potent SCF antagonist.
Human CD117/c-kit PE‑conjugated Antibody
R&D Systems | Catalog # FAB332P
Key Product Details
Species Reactivity
Validated:
Cited:
Applications
Validated:
Cited:
Label
Antibody Source
Product Specifications
Immunogen
Gln26-Thr520
Accession # P10721
Specificity
Clonality
Host
Isotype
Scientific Data Images for Human CD117/c-kit PE‑conjugated Antibody
Detection of CD117/c-kit in TF‑1 Human Cell Line by Flow Cytometry.
TF-1 human erythroleukemic cell line was stained with Mouse Anti-Human CD117/c-kit PE-conjugated Monoclonal Antibody (Catalog # FAB332P, filled histogram) or isotype control antibody (Catalog # IC002P, open histogram). View our protocol for Staining Membrane-associated Proteins.
Applications for Human CD117/c-kit PE‑conjugated Antibody
Flow Cytometry
Sample: TF‑1 human erythroleukemic cell line
Spectra Viewer
Plan Your Experiments
Use our spectra viewer to interactively plan your experiments, assessing multiplexing options. View the excitation and emission spectra for our fluorescent dye range and other commonly used dyes.
Spectra ViewerFlow Cytometry Panel Builder
Bio-Techne Knows Flow Cytometry
Save time and reduce costly mistakes by quickly finding compatible reagents using the Panel Builder Tool.
Advanced Features
- Spectra Viewer - Custom analysis of spectra from multiple fluorochromes
- Spillover Popups - Visualize the spectra of individual fluorochromes
- Antigen Density Selector - Match fluorochrome brightness with antigen density
Formulation, Preparation, and Storage
Purification
Formulation
Shipping
Stability & Storage
- 12 months from date of receipt, 2 to 8 °C as supplied.
Background: CD117/c-kit
Long Name
Alternate Names
Gene Symbol
UniProt
Additional CD117/c-kit Products
Product Documents for Human CD117/c-kit PE‑conjugated Antibody
Product Specific Notices for Human CD117/c-kit PE‑conjugated Antibody
For research use only
Related Research Areas
Citations for Human CD117/c-kit PE‑conjugated Antibody
Customer Reviews for Human CD117/c-kit PE‑conjugated Antibody
There are currently no reviews for this product. Be the first to review Human CD117/c-kit PE‑conjugated Antibody and earn rewards!
Have you used Human CD117/c-kit PE‑conjugated Antibody?
Submit a review and receive an Amazon gift card!
$25/€18/£15/$25CAN/¥2500 Yen for a review with an image
$10/€7/£6/$10CAN/¥1110 Yen for a review without an image
Submit a review
Protocols
Find general support by application which include: protocols, troubleshooting, illustrated assays, videos and webinars.
- 7-Amino Actinomycin D (7-AAD) Cell Viability Flow Cytometry Protocol
- Extracellular Membrane Flow Cytometry Protocol
- Flow Cytometry Protocol for Cell Surface Markers
- Flow Cytometry Protocol for Staining Membrane Associated Proteins
- Flow Cytometry Staining Protocols
- Flow Cytometry Troubleshooting Guide
- Intracellular Flow Cytometry Protocol Using Alcohol (Methanol)
- Intracellular Flow Cytometry Protocol Using Detergents
- Intracellular Nuclear Staining Flow Cytometry Protocol Using Detergents
- Intracellular Staining Flow Cytometry Protocol Using Alcohol Permeabilization
- Intracellular Staining Flow Cytometry Protocol Using Detergents to Permeabilize Cells
- Propidium Iodide Cell Viability Flow Cytometry Protocol
- Protocol for the Characterization of Human Th22 Cells
- Protocol for the Characterization of Human Th9 Cells
- Protocol: Annexin V and PI Staining by Flow Cytometry
- Protocol: Annexin V and PI Staining for Apoptosis by Flow Cytometry
- Troubleshooting Guide: Fluorokine Flow Cytometry Kits
- View all Protocols, Troubleshooting, Illustrated assays and Webinars