CD117/c-kit Antibody (2B8) - BSA Free
Novus Biologicals | Catalog # NB100-77477
Key Product Details
Species Reactivity
Validated:
Human, Mouse
Cited:
Human, Mouse
Applications
Validated:
Immunohistochemistry, Immunohistochemistry-Frozen, Flow Cytometry, Immunocytochemistry/ Immunofluorescence, Immunoprecipitation
Cited:
Flow Cytometry, Immunocytochemistry/ Immunofluorescence, IF/IHC
Label
Unconjugated
Antibody Source
Monoclonal Rat IgG2b Kappa Clone # 2B8
Format
BSA Free
Loading...
Product Specifications
Immunogen
Mouse bone marrow mast cells
Reactivity Notes
Human reactivity reported in scientific literature (PMID: 23967247).
Marker
Hematopoietic Stem Cell Marker
Clonality
Monoclonal
Host
Rat
Isotype
IgG2b Kappa
Description
Novus Biologicals Rat CD117/c-kit Antibody (2B8) - BSA Free (NB100-77477) is a monoclonal antibody validated for use in IHC, Flow, ICC/IF and IP. Anti-CD117/c-kit Antibody: Cited in 11 publications. All Novus Biologicals antibodies are covered by our 100% guarantee.
Scientific Data Images for CD117/c-kit Antibody (2B8) - BSA Free
Flow Cytometry: CD117/c-kit Antibody (2B8) - BSA Free [NB100-77477]
Flow Cytometry: CD117/c-kit Antibody (2B8) [NB100-77477] - Detection of CD117/c-kit in Mouse Bone Marrow Cells by Flow Cytometry. Mouse bone marrow cells were stained with PE-conjugated Rat Anti-Mouse B220/CD45R (Catalog # FAB1217P) and Rat Anti-Mouse CD117/c-kit Monoclonal Antibody (Catalog # NB100-77477, top panel) or isotype control antibody (Catalog # MAB0061, bottom panel), followed by APC-conjugated Goat Anti-Rat IgG (Catalog # F0113).Flow Cytometry: CD117/c-kit Antibody (2B8) - BSA Free [NB100-77477]
CD117-c-kit-Antibody-2B8-Flow-Cytometry-NB100-77477-img0004.jpgFlow Cytometry: CD117/c-kit Antibody (2B8) - BSA Free [NB100-77477]
Flow Cytometry: CD117/c-kit Antibody (2B8) [NB100-77477] - C57BL/6 bone marrow cells stained with 2B8 PE and CD11b FITC.Flow Cytometry: CD117/c-kit Antibody (2B8) - BSA Free [NB100-77477] -
Identification of c-kit expressing bone marrow cells.Double labeling of mouse bone marrow cells with anti-CD45 antibody and (a) Kit-129 aptamer or (b) rabbit anti-c-kit antibody 2B8.Applications for CD117/c-kit Antibody (2B8) - BSA Free
Application
Recommended Usage
Flow Cytometry
0.6 ug/10^6 cells in 100 uL
Immunocytochemistry/ Immunofluorescence
reported in scientific literature (PMID 28097227)
Immunohistochemistry
1:20 - 1:1000
Immunohistochemistry-Frozen
1:20 - 1:1000
Immunoprecipitation
1:20 - 1:1000
Application Notes
Each lot of this antibody is quality control tested by immunofluorescent staining with flow cytometric analysis.
Reviewed Applications
Read 1 review rated 1 using NB100-77477 in the following applications:
Flow Cytometry Panel Builder
Bio-Techne Knows Flow Cytometry
Save time and reduce costly mistakes by quickly finding compatible reagents using the Panel Builder Tool.
Advanced Features
- Spectra Viewer - Custom analysis of spectra from multiple fluorochromes
- Spillover Popups - Visualize the spectra of individual fluorochromes
- Antigen Density Selector - Match fluorochrome brightness with antigen density
Formulation, Preparation, and Storage
Purification
Protein A or G purified
Formulation
PBS
Format
BSA Free
Preservative
0.02% Sodium Azide
Concentration
1.0 mg/ml
Shipping
The product is shipped with polar packs. Upon receipt, store it immediately at the temperature recommended below.
Stability & Storage
Store at 4C. Do not freeze.
Background: CD117/c-kit
Long Name
Stem Cell Factor Receptor
Alternate Names
c-kit, CD117, ckit, KIT, PBT, SCF R, SCFR
Gene Symbol
KIT
Additional CD117/c-kit Products
Product Documents for CD117/c-kit Antibody (2B8) - BSA Free
Product Specific Notices for CD117/c-kit Antibody (2B8) - BSA Free
This product is for research use only and is not approved for use in humans or in clinical diagnosis. Primary Antibodies are guaranteed for 1 year from date of receipt.
Related Research Areas
Citations for CD117/c-kit Antibody (2B8) - BSA Free
Customer Reviews for CD117/c-kit Antibody (2B8) - BSA Free (1)
1 out of 5
1 Customer Rating
Have you used CD117/c-kit Antibody (2B8) - BSA Free?
Submit a review and receive an Amazon gift card!
$25/€18/£15/$25CAN/¥2500 Yen for a review with an image
$10/€7/£6/$10CAN/¥1110 Yen for a review without an image
Submit a review
Customer Images
Showing
1
-
1 of
1 review
Showing All
Filter By:
-
Application: Immunohistochemistry-ParaffinSample Tested: human skinSpecies: HumanVerified Customer | Posted 01/02/2018We tested CD117/c-kit antibody (2B8) for IHC-P (human skin) and confirmed that it did not work to detect human melanocytes which are reportedly positive for ckit, indicating that this product is not applicable for FFPE section.
There are no reviews that match your criteria.
Protocols
Find general support by application which include: protocols, troubleshooting, illustrated assays, videos and webinars.
- 7-Amino Actinomycin D (7-AAD) Cell Viability Flow Cytometry Protocol
- Antigen Retrieval Protocol (PIER)
- Antigen Retrieval for Frozen Sections Protocol
- Appropriate Fixation of IHC/ICC Samples
- Cellular Response to Hypoxia Protocols
- Chromogenic IHC Staining of Formalin-Fixed Paraffin-Embedded (FFPE) Tissue Protocol
- Chromogenic Immunohistochemistry Staining of Frozen Tissue
- Detection & Visualization of Antibody Binding
- Extracellular Membrane Flow Cytometry Protocol
- Flow Cytometry Protocol for Cell Surface Markers
- Flow Cytometry Protocol for Staining Membrane Associated Proteins
- Flow Cytometry Staining Protocols
- Flow Cytometry Troubleshooting Guide
- Fluorescent IHC Staining of Frozen Tissue Protocol
- Graphic Protocol for Heat-induced Epitope Retrieval
- Graphic Protocol for the Preparation and Fluorescent IHC Staining of Frozen Tissue Sections
- Graphic Protocol for the Preparation and Fluorescent IHC Staining of Paraffin-embedded Tissue Sections
- Graphic Protocol for the Preparation of Gelatin-coated Slides for Histological Tissue Sections
- ICC Cell Smear Protocol for Suspension Cells
- ICC Immunocytochemistry Protocol Videos
- ICC for Adherent Cells
- IHC Sample Preparation (Frozen sections vs Paraffin)
- Immunocytochemistry (ICC) Protocol
- Immunocytochemistry Troubleshooting
- Immunofluorescence of Organoids Embedded in Cultrex Basement Membrane Extract
- Immunofluorescent IHC Staining of Formalin-Fixed Paraffin-Embedded (FFPE) Tissue Protocol
- Immunohistochemistry (IHC) and Immunocytochemistry (ICC) Protocols
- Immunohistochemistry Frozen Troubleshooting
- Immunohistochemistry Paraffin Troubleshooting
- Immunoprecipitation Protocol
- Intracellular Flow Cytometry Protocol Using Alcohol (Methanol)
- Intracellular Flow Cytometry Protocol Using Detergents
- Intracellular Nuclear Staining Flow Cytometry Protocol Using Detergents
- Intracellular Staining Flow Cytometry Protocol Using Alcohol Permeabilization
- Intracellular Staining Flow Cytometry Protocol Using Detergents to Permeabilize Cells
- Preparing Samples for IHC/ICC Experiments
- Preventing Non-Specific Staining (Non-Specific Binding)
- Primary Antibody Selection & Optimization
- Propidium Iodide Cell Viability Flow Cytometry Protocol
- Protocol for Heat-Induced Epitope Retrieval (HIER)
- Protocol for Making a 4% Formaldehyde Solution in PBS
- Protocol for VisUCyte™ HRP Polymer Detection Reagent
- Protocol for the Characterization of Human Th22 Cells
- Protocol for the Characterization of Human Th9 Cells
- Protocol for the Fluorescent ICC Staining of Cell Smears - Graphic
- Protocol for the Fluorescent ICC Staining of Cultured Cells on Coverslips - Graphic
- Protocol for the Preparation & Fixation of Cells on Coverslips
- Protocol for the Preparation and Chromogenic IHC Staining of Frozen Tissue Sections
- Protocol for the Preparation and Chromogenic IHC Staining of Frozen Tissue Sections - Graphic
- Protocol for the Preparation and Chromogenic IHC Staining of Paraffin-embedded Tissue Sections
- Protocol for the Preparation and Chromogenic IHC Staining of Paraffin-embedded Tissue Sections - Graphic
- Protocol for the Preparation and Fluorescent ICC Staining of Cells on Coverslips
- Protocol for the Preparation and Fluorescent ICC Staining of Non-adherent Cells
- Protocol for the Preparation and Fluorescent ICC Staining of Stem Cells on Coverslips
- Protocol for the Preparation and Fluorescent IHC Staining of Frozen Tissue Sections
- Protocol for the Preparation and Fluorescent IHC Staining of Paraffin-embedded Tissue Sections
- Protocol for the Preparation of Gelatin-coated Slides for Histological Tissue Sections
- Protocol for the Preparation of a Cell Smear for Non-adherent Cell ICC - Graphic
- Protocol: Annexin V and PI Staining by Flow Cytometry
- Protocol: Annexin V and PI Staining for Apoptosis by Flow Cytometry
- TUNEL and Active Caspase-3 Detection by IHC/ICC Protocol
- The Importance of IHC/ICC Controls
- Troubleshooting Guide: Fluorokine Flow Cytometry Kits
- Troubleshooting Guide: Immunohistochemistry
- View all Protocols, Troubleshooting, Illustrated assays and Webinars