Human L1CAM Antibody
R&D Systems | Catalog # MAB7773
Key Product Details
Species Reactivity
Applications
Label
Antibody Source
Product Specifications
Immunogen
(Ile20Glu1120) & (Arg864Glu1120)
Accession # CAA42508
Specificity
Clonality
Host
Isotype
Scientific Data Images for Human L1CAM Antibody
Detection of Human L1CAM by Western Blot.
Western blot shows lysates of HeLa human cervical epithelial carcinoma cell line and human brain (motor cortex). PVDF membrane was probed with 2 µg/mL of Rabbit Anti-Human L1CAM Monoclonal Antibody (Catalog # MAB7773) followed by HRP-conjugated Anti-Rabbit IgG Secondary Antibody (HAF008). A specific band was detected for L1CAM at approximately 250 kDa (as indicated). This experiment was conducted under reducing conditions and using Western Blot Buffer Group 1.Detection of L1CAM in HeLa Human Cell Line by Flow Cytometry.
HeLa human cervical epithelial cell line was stained with Rabbit Anti-Human L1CAM Monoclonal Antibody (Catalog # MAB7773, filled histogram) or Rabbit IgG isotype control antibody (MAB1050, open histogram), followed by Phycoerythrin-conjugated Anti-Rabbit IgG Secondary Antibody (F0110). Staining was performed using our Staining Membrane-associated Proteins protocol.L1CAM in HeLa Human Cell Line.
L1CAM was detected in immersion fixed HeLa human cervical epithelial carcinoma cell line (positive staining) and Daudi human Burkitt's lymphoma cell line (negative staining) using Rabbit Anti-Human L1CAM Monoclonal Antibody (Catalog # MAB7773) at 3 µg/mL for 3 hours at room temperature. Cells were stained using the NorthernLights™ 557-conjugated Anti-Rabbit IgG Secondary Antibody (red; NL004) and counterstained with DAPI (blue). Specific staining was localized to cell membrane. Staining was performed using our protocol for Fluorescent ICC Staining of Non-adherent Cells.L1CAM in MCF‑7 Human Cell Line.
L1CAM was detected in immersion fixed MCF‑7 human breast cancer cell line (positive staining) and Daudi human Burkitt's lymphoma cell line (negative staining) using Rabbit Anti-Human L1CAM Monoclonal Antibody (Catalog # MAB7773) at 3 µg/mL for 3 hours at room temperature. Cells were stained using the NorthernLights™ 557-conjugated Anti-Rabbit IgG Secondary Antibody (red; NL004) and counterstained with DAPI (blue). Specific staining was localized to cell membrane. Staining was performed using our protocol for Fluorescent ICC Staining of Non-adherent Cells.Detection of Human L1CAM by Simple WesternTM.
Simple Western lane view shows lysates of HeLa human cervical epithelial carcinoma cell line, loaded at 0.2 mg/mL. A specific band was detected for L1CAM at approximately 338 kDa (as indicated) using 20 µg/mL of Rabbit Anti-Human L1CAM Monoclonal Antibody (Catalog # MAB7773). This experiment was conducted under reducing conditions and using the 66-440 kDa separation system.Applications for Human L1CAM Antibody
Flow Cytometry
Sample: HeLa human cervical epithelial cell line
Immunocytochemistry
Sample: Immersion fixed HeLa human cervical epithelial carcinoma cell line and MCF‑7 human breast cancer cell line
Simple Western
Sample: HeLa human cervical epithelial carcinoma cell line
Western Blot
Sample: HeLa human cervical epithelial carcinoma cell line and human brain (motor cortex)
Flow Cytometry Panel Builder
Bio-Techne Knows Flow Cytometry
Save time and reduce costly mistakes by quickly finding compatible reagents using the Panel Builder Tool.
Advanced Features
- Spectra Viewer - Custom analysis of spectra from multiple fluorochromes
- Spillover Popups - Visualize the spectra of individual fluorochromes
- Antigen Density Selector - Match fluorochrome brightness with antigen density
Formulation, Preparation, and Storage
Purification
Reconstitution
Reconstitute at 0.5 mg/mL in sterile PBS. For liquid material, refer to CoA for concentration.
Formulation
Shipping
Stability & Storage
- 12 months from date of receipt, -20 to -70 °C as supplied.
- 1 month, 2 to 8 °C under sterile conditions after reconstitution.
- 6 months, -20 to -70 °C under sterile conditions after reconstitution.
Calculators
Background: L1CAM
References
- Maness, P.F. and M. Schachner (2007) Nat. Neurosci. 10:19.
- Wei, C.H. and S.E. Ryu (2012) Exp. Mol. Med. 44:413.
- Faspel, J. and M. Grumet (2003) Front. Biosci. 8:1210.
- Herron, L.R. et al. (2009) Biochem. J. 419:519.
- Rathjen, F.G. and M. Schachner (1984) EMBO. J. 3:1.
- Keifel, H. et al. (2011) Trends Mol. Med. 17:178.
- Dihne, M. et al. (2003) J. Neurosci. 23:6638.
- Kadmon, G. et al. (1998) Dev. Immunol. 6:205.
- Itoh, K. et al. (2000) J. Neurosci. Res. 60:579.
- Jouet, M. et al. (1995) Mol. Brain Res. 30:378.
- He, Q. et al. (2012) Neurosci. Lett. 521:57.
- Thor, G. et al. (1987) EMBO J. 6:2581.
- Sadoul, K. et al. (1988) J. Neurochem. 50:510.
- Hubbe, M. et al. (1993) Eur. J. Immunol. 23:2927.
- Hoja-Lukowicz, D. et al. (2012) Glycoconj J. Apr 29. [Epub ahead of print].
- Geismann, C. et al. (2009) Cancer Res. 69:4517.
- Tischler, V. et al. (2011) Mol. Cancer 10:127.
- Mujoo, K. et al. (1986) J. Biol. Chem. 261:10299.
- Kobayashi, M. et al. (1991) Biochim. Biophys. Acta 1090:238.
- Hlavin, M.L. and V. Lemmon (1991) Genomics 11:416.
- Castellani, V. et al. (2002) EMBO J. 21:6348.
- Zhao, X. and C-H Siu (1995) J. Biol. Chem. 270:29413.
- Oleszewski, M. et al. (1999) J. Biol. Chem. 274:24602.
- Felding-Habermann, B. et al. (1997) J. Cell Biol. 139:1567.
- Kamiguchi, H. et al. (1998) J. Neurosci. 18:5311.
- De Angelis, E. et al. (2001) J. Biol. Chem. 276:32738.
- Montgomery, A.M.P. et al. (1996) J. Cell Biol. 132:475.
- Sadoul, R. et al. (1989) J. Neurochem. 53:1471.
- Reidle, S. et al. (2009) Biochem. J. 420:391.
- Lutz, D. et al. (2012) J. Biol. Chem. 287:17161.
Long Name
Alternate Names
Gene Symbol
UniProt
Additional L1CAM Products
Product Documents for Human L1CAM Antibody
Certificate of Analysis
To download a Certificate of Analysis, please enter a lot or batch number in the search box below.
Note: Certificate of Analysis not available for kit components.
Product Specific Notices for Human L1CAM Antibody
For research use only
Customer Reviews for Human L1CAM Antibody
There are currently no reviews for this product. Be the first to review Human L1CAM Antibody and earn rewards!
Have you used Human L1CAM Antibody?
Submit a review and receive an Amazon gift card!
$25/€18/£15/$25CAN/¥2500 Yen for a review with an image
$10/€7/£6/$10CAN/¥1110 Yen for a review without an image
Submit a review
Protocols
Find general support by application which include: protocols, troubleshooting, illustrated assays, videos and webinars.
- 7-Amino Actinomycin D (7-AAD) Cell Viability Flow Cytometry Protocol
- Appropriate Fixation of IHC/ICC Samples
- Cellular Response to Hypoxia Protocols
- ClariTSA™ Fluorophore Kits
- Detection & Visualization of Antibody Binding
- Extracellular Membrane Flow Cytometry Protocol
- Flow Cytometry Protocol for Cell Surface Markers
- Flow Cytometry Protocol for Staining Membrane Associated Proteins
- Flow Cytometry Staining Protocols
- Flow Cytometry Troubleshooting Guide
- ICC Cell Smear Protocol for Suspension Cells
- ICC Immunocytochemistry Protocol Videos
- ICC for Adherent Cells
- Immunocytochemistry (ICC) Protocol
- Immunocytochemistry Troubleshooting
- Immunofluorescence of Organoids Embedded in Cultrex Basement Membrane Extract
- Immunohistochemistry (IHC) and Immunocytochemistry (ICC) Protocols
- Intracellular Flow Cytometry Protocol Using Alcohol (Methanol)
- Intracellular Flow Cytometry Protocol Using Detergents
- Intracellular Nuclear Staining Flow Cytometry Protocol Using Detergents
- Intracellular Staining Flow Cytometry Protocol Using Alcohol Permeabilization
- Intracellular Staining Flow Cytometry Protocol Using Detergents to Permeabilize Cells
- Preparing Samples for IHC/ICC Experiments
- Preventing Non-Specific Staining (Non-Specific Binding)
- Primary Antibody Selection & Optimization
- Propidium Iodide Cell Viability Flow Cytometry Protocol
- Protocol for Liperfluo
- Protocol for VisUCyte™ HRP Polymer Detection Reagent
- Protocol for the Characterization of Human Th22 Cells
- Protocol for the Characterization of Human Th9 Cells
- Protocol for the Fluorescent ICC Staining of Cell Smears - Graphic
- Protocol for the Fluorescent ICC Staining of Cultured Cells on Coverslips - Graphic
- Protocol for the Preparation and Fluorescent ICC Staining of Cells on Coverslips
- Protocol for the Preparation and Fluorescent ICC Staining of Non-adherent Cells
- Protocol for the Preparation and Fluorescent ICC Staining of Stem Cells on Coverslips
- Protocol for the Preparation of a Cell Smear for Non-adherent Cell ICC - Graphic
- Protocol: Annexin V and PI Staining by Flow Cytometry
- Protocol: Annexin V and PI Staining for Apoptosis by Flow Cytometry
- R&D Systems Quality Control Western Blot Protocol
- TUNEL and Active Caspase-3 Detection by IHC/ICC Protocol
- The Importance of IHC/ICC Controls
- Troubleshooting Guide: Fluorokine Flow Cytometry Kits
- Troubleshooting Guide: Western Blot Figures
- Western Blot Conditions
- Western Blot Protocol
- Western Blot Protocol for Cell Lysates
- Western Blot Troubleshooting
- Western Blot Troubleshooting Guide
- View all Protocols, Troubleshooting, Illustrated assays and Webinars