Human OCIL/CLEC2d Antibody
R&D Systems | Catalog # AF3480
Key Product Details
Species Reactivity
Validated:
Cited:
Applications
Validated:
Cited:
Label
Antibody Source
Product Specifications
Immunogen
Ser57-Val191
Accession # Q9UHP7
Specificity
Clonality
Host
Isotype
Scientific Data Images for Human OCIL/CLEC2d Antibody
Detection of OCIL/CLEC2d in Raji Human Cell Line by Flow Cytometry.
Raji human Burkitt's lymphoma cell line was stained with Goat Anti-Human OCIL/CLEC2d Antigen Affinity-purified Polyclonal Antibody (Catalog # AF3480, filled histogram) or control antibody (Catalog # AB-108-C, open histogram), followed by Phycoerythrin-conjugated Anti-Goat IgG Secondary Antibody (Catalog # F0107).
Detection of OCIL/CLEC2d by Immunohistochemistry
LLT1 is highly expressed in immune-privileged sites.Lectin-like transcript 1 (LLT1) and isotype control stainings of testes (A), brain (B) and placenta (C) using the anti-LLT1 2H7 mAb (1/500). Representative image of three independent experiments. 20× magnification. Image collected and cropped by CiteAb from the following open publication (https://pubmed.ncbi.nlm.nih.gov/28413611), licensed under a CC-BY license. Not internally tested by R&D Systems.Detection of OCIL/CLEC2d by Immunohistochemistry
LLT1 is highly expressed in immune-privileged sites.Lectin-like transcript 1 (LLT1) and isotype control stainings of testes (A), brain (B) and placenta (C) using the anti-LLT1 2H7 mAb (1/500). Representative image of three independent experiments. 20× magnification. Image collected and cropped by CiteAb from the following open publication (https://pubmed.ncbi.nlm.nih.gov/28413611), licensed under a CC-BY license. Not internally tested by R&D Systems.Detection of OCIL/CLEC2d by Immunohistochemistry
LLT1 is expressed on B cells and monocytes.Lectin-like transcript 1 (LLT1) (stained using the 2H7 mAb) and CD161 levels were measured by flow cytometry in monocytes (M) and lymphocytes (L). (A) The gating strategy, (B) representative and cumulative data for the expression of CD161 (blue) and LLT1 (green) compared to the isotype control (IC, red) (n=4). (C) Representative image of LLT1 staining in human tonsil tissue using the 2H7 anti-LLT1 antibody (10×; n=6), together with a representative FACS plot of LLT1 staining of purified tonsillar B cells with the 2H7 antibody. The GC population is highlighted (rectangle; n=8). (D) Immunofluorescent co-staining of LLT1 (red) and CD68 (green) in lung and liver (scale bar = 100μm). Representative of two independent experiments. Image collected and cropped by CiteAb from the following open publication (https://pubmed.ncbi.nlm.nih.gov/28413611), licensed under a CC-BY license. Not internally tested by R&D Systems.Detection of OCIL/CLEC2d by Immunohistochemistry
LLT1 is highly expressed in immune-privileged sites.Lectin-like transcript 1 (LLT1) and isotype control stainings of testes (A), brain (B) and placenta (C) using the anti-LLT1 2H7 mAb (1/500). Representative image of three independent experiments. 20× magnification. Image collected and cropped by CiteAb from the following open publication (https://pubmed.ncbi.nlm.nih.gov/28413611), licensed under a CC-BY license. Not internally tested by R&D Systems.Applications for Human OCIL/CLEC2d Antibody
CyTOF-ready
Flow Cytometry
Sample: Raji human Burkitt's lymphoma cell line
Western Blot
Sample: Recombinant Human OCIL/CLEC2d
Flow Cytometry Panel Builder
Bio-Techne Knows Flow Cytometry
Save time and reduce costly mistakes by quickly finding compatible reagents using the Panel Builder Tool.
Advanced Features
- Spectra Viewer - Custom analysis of spectra from multiple fluorochromes
- Spillover Popups - Visualize the spectra of individual fluorochromes
- Antigen Density Selector - Match fluorochrome brightness with antigen density
Formulation, Preparation, and Storage
Purification
Reconstitution
Reconstitute at 0.2 mg/mL in sterile PBS. For liquid material, refer to CoA for concentration.
Formulation
Shipping
Stability & Storage
- 12 months from date of receipt, -20 to -70 °C as supplied.
- 1 month, 2 to 8 °C under sterile conditions after reconstitution.
- 6 months, -20 to -70 °C under sterile conditions after reconstitution.
Calculators
Background: OCIL/CLEC2d
Long Name
Alternate Names
Gene Symbol
UniProt
Additional OCIL/CLEC2d Products
Product Documents for Human OCIL/CLEC2d Antibody
Certificate of Analysis
To download a Certificate of Analysis, please enter a lot or batch number in the search box below.
Note: Certificate of Analysis not available for kit components.
Product Specific Notices for Human OCIL/CLEC2d Antibody
For research use only
Related Research Areas
Citations for Human OCIL/CLEC2d Antibody
Customer Reviews for Human OCIL/CLEC2d Antibody
There are currently no reviews for this product. Be the first to review Human OCIL/CLEC2d Antibody and earn rewards!
Have you used Human OCIL/CLEC2d Antibody?
Submit a review and receive an Amazon gift card!
$25/€18/£15/$25CAN/¥2500 Yen for a review with an image
$10/€7/£6/$10CAN/¥1110 Yen for a review without an image
Submit a review
Protocols
Find general support by application which include: protocols, troubleshooting, illustrated assays, videos and webinars.
- 7-Amino Actinomycin D (7-AAD) Cell Viability Flow Cytometry Protocol
- Cellular Response to Hypoxia Protocols
- Extracellular Membrane Flow Cytometry Protocol
- Flow Cytometry Protocol for Cell Surface Markers
- Flow Cytometry Protocol for Staining Membrane Associated Proteins
- Flow Cytometry Staining Protocols
- Flow Cytometry Troubleshooting Guide
- Intracellular Flow Cytometry Protocol Using Alcohol (Methanol)
- Intracellular Flow Cytometry Protocol Using Detergents
- Intracellular Nuclear Staining Flow Cytometry Protocol Using Detergents
- Intracellular Staining Flow Cytometry Protocol Using Alcohol Permeabilization
- Intracellular Staining Flow Cytometry Protocol Using Detergents to Permeabilize Cells
- Propidium Iodide Cell Viability Flow Cytometry Protocol
- Protocol for the Characterization of Human Th22 Cells
- Protocol for the Characterization of Human Th9 Cells
- Protocol: Annexin V and PI Staining by Flow Cytometry
- Protocol: Annexin V and PI Staining for Apoptosis by Flow Cytometry
- R&D Systems Quality Control Western Blot Protocol
- Troubleshooting Guide: Fluorokine Flow Cytometry Kits
- Troubleshooting Guide: Western Blot Figures
- Western Blot Conditions
- Western Blot Protocol
- Western Blot Protocol for Cell Lysates
- Western Blot Troubleshooting
- Western Blot Troubleshooting Guide
- View all Protocols, Troubleshooting, Illustrated assays and Webinars