Key Product Details

Species Reactivity

Validated:

Human

Cited:

Human

Applications

Validated:

Western Blot, ELISA Capture (Matched Antibody Pair), Neutralization

Cited:

Immunohistochemistry-Paraffin, Western Blot, Neutralization

Label

Unconjugated

Antibody Source

Monoclonal Mouse IgG1 Clone # 60910
Loading...

Product Specifications

Immunogen

E. coli-derived recombinant human CXCL6/GCP-2
Val40-Asn114
Accession # P80162

Specificity

Detects human CXCL6/GCP‑2 in ELISAs and Western blots. In sandwich immunoassays, less than 0.04% cross-reactivity with recombinant human (rh) NAP-2, rhGRO alpha, rhGRO beta, rhBLC, rhENA-78, recombinant mouse (rm) CXCL6, rmMIP-2, rhIL-8, rhIP-10, rhMIG, rhSDF-1 alpha, and rhSDF-1 beta is observed.

Clonality

Monoclonal

Host

Mouse

Isotype

IgG1

Endotoxin Level

<0.10 EU per 1 μg of the antibody by the LAL method.

Scientific Data Images for Human CXCL6/GCP‑2 Antibody

Chemotaxis Induced by CXCL6/GCP‑2 and Neutral-ization by Human CXCL6/ GCP‑2 Antibody.

Chemotaxis Induced by CXCL6/GCP‑2 and Neutral-ization by Human CXCL6/ GCP‑2 Antibody.

Recombinant Human CXCL6/ GCP-2 (Catalog # 333-GC) induces chemotaxis in the BaF3 mouse pro-B cell line transfected with human CXCR2 in a dose-dependent manner (orange line), as measured by Resazurin (Catalog # AR002). Under these conditions, chemotaxis elicited by CXCL6/GCP-2 is neutralized (green line) by increasing concentrations of Mouse Anti-Human CXCL6/GCP-2 Monoclonal Antibody (Catalog # MAB333). The ND50 is typically 8-30 µg/mL.

Applications for Human CXCL6/GCP‑2 Antibody

Application
Recommended Usage

Western Blot

1 µg/mL
Sample: Recombinant Human CXCL6/GCP‑2 (Catalog # 333-GC)

Neutralization

Measured by its ability to neutralize CXCL6/GCP‑2-induced chemotaxis in the BaF3 mouse pro‑B cell line transfected with human CXCR2. The Neutralization Dose (ND50) is typically 8-30 μg/mL in the presence of 80 ng/mL Recombinant Human CXCL6/GCP‑2.

Human CXCL6/GCP-2 Sandwich Immunoassay

ELISA Capture (Matched Antibody Pair)
Recommended Concentration: 2-8 µg/mL
Use in combination with these reagents:
  • Detection Reagent: Human CXCL6/GCP‑2 Biotinylated Antibody (Catalog # BAF333)
  • Standard: Recombinant Human CXCL6/GCP-2 Protein (Catalog # 333-GC)
Please Note: Optimal dilutions of this antibody should be experimentally determined.

Reviewed Applications

Read 2 reviews rated 4 using MAB333 in the following applications:

Formulation, Preparation, and Storage

Purification

Protein A or G purified from ascites

Reconstitution

Reconstitute at 0.5 mg/mL in sterile PBS. For liquid material, refer to CoA for concentration.


Loading...

Formulation

Lyophilized from a 0.2 μm filtered solution in PBS with Trehalose. *Small pack size (SP) is supplied either lyophilized or as a 0.2 µm filtered solution in PBS.

Shipping

Lyophilized product is shipped at ambient temperature. Liquid small pack size (-SP) is shipped with polar packs. Upon receipt, store immediately at the temperature recommended below.

Stability & Storage

Use a manual defrost freezer and avoid repeated freeze-thaw cycles.
  • 12 months from date of receipt, -20 to -70 °C as supplied.
  • 1 month, 2 to 8 °C under sterile conditions after reconstitution.
  • 6 months, -20 to -70 °C under sterile conditions after reconstitution.

Calculators

The reconstitution calculator allows you to quickly calculate the volume of a reagent to reconstitute your vial. Simply enter the mass of reagent and the target concentration and the calculator will determine the rest.

=
÷

Background: CXCL6/GCP-2

CXCL6, also known as Granulocyte Chemotactic Protein 2 (GCP-2), belongs to the CXC chemokine family. It functions as a neutrophil chemoattractant through interactions with CXCR2.

Alternate Names

GCP-2

Entrez Gene IDs

6372 (Human)

Gene Symbol

CXCL6

UniProt

Additional CXCL6/GCP-2 Products

Product Documents for Human CXCL6/GCP‑2 Antibody

Certificate of Analysis

To download a Certificate of Analysis, please enter a lot or batch number in the search box below.

Note: Certificate of Analysis not available for kit components.

Product Specific Notices for Human CXCL6/GCP‑2 Antibody

For research use only

Related Research Areas

Citations for Human CXCL6/GCP‑2 Antibody

Customer Reviews for Human CXCL6/GCP‑2 Antibody (2)

4 out of 5
2 Customer Ratings
5 Stars
0%
4 Stars
100%
3 Stars
0%
2 Stars
0%
1 Stars
0%

Have you used Human CXCL6/GCP‑2 Antibody?

Submit a review and receive an Amazon gift card!

$25/€18/£15/$25CAN/¥2500 Yen for a review with an image

$10/€7/£6/$10CAN/¥1110 Yen for a review without an image

Submit a review
Amazon Gift Card

Customer Images


Showing  1 - 2 of 2 reviews Showing All
Filter By:
  • Human CXCL6/GCP-2 Antibody
    Name: Anonymous
    Application: Western Blot
    Sample Tested: HUVEC human umbilical vein endothelial cells
    Species: Human
    Verified Customer | Posted 11/12/2025
    Human CXCL6/GCP‑2 Antibody MAB333
  • Human CXCL6/GCP-2 Antibody
    Name: Ruhul Choudhury
    Application: Block/Neutralize
    Sample Tested: Uterine endothelial cells conditioned medium
    Species: Mouse
    Verified Customer | Posted 01/20/2017

There are no reviews that match your criteria.

Showing  1 - 2 of 2 reviews Showing All

FAQs

No product specific FAQs exist for this product.

View all FAQs for Antibodies