Bcl-2 antagonist of cell death (BAD) is an 18 kDa cytoplasmic protein in the Bcl-2 family. It functions as a pro-apoptotic molecule by dimerizing with and inhibiting the anti-apoptotic proteins Bcl-2 and Bcl-xL. Prosurvival signals trigger the phosphorylation of BAD on Ser115, disrupting its interaction with Bcl-2 and Bcl-xL and resulting in protection from apoptosis. Over amino acid 1-21, human BAD shares 81 % aa sequence identity with mouse and rat BAD.
Key Product Details
Species Reactivity
Validated:
Human, Mouse
Cited:
Mouse, Rat
Applications
Validated:
Western Blot, Immunocytochemistry
Cited:
Immunohistochemistry, Western Blot, Bioassay
Label
Unconjugated
Antibody Source
Polyclonal Rabbit IgG
Loading...
Product Specifications
Immunogen
KLH-coupled human Bad synthetic peptide
MFQIPEFEPSEQEDSSSAERGC
Accession # Q92934
MFQIPEFEPSEQEDSSSAERGC
Accession # Q92934
Specificity
Detects human and mouse Bad in Western blots.
Clonality
Polyclonal
Host
Rabbit
Isotype
IgG
Scientific Data Images for Human/Mouse Bad aa 1‑21 Antibody
Detection of Human/Mouse Bad by Western Blot.
Western blot shows lysates of A431 human epithelial carcinoma cell line, Jurkat human acute T cell leukemia cell line, HepG2 human hepatocellular carcinoma cell line, and L-929 mouse fibroblast cell line. PVDF membrane was probed with 1 µg/mL of Rabbit Anti-Human/Mouse Bad Antigen Affinity-purified Polyclonal Antibody (Catalog # AF819) followed by HRP-conjugated Anti-Rabbit IgG Secondary Antibody (Catalog # HAF008). A specific band was detected for Bad at approximately 22 kDa (as indicated). This experiment was conducted under reducing conditions and using Immunoblot Buffer Group 2.Bad in Jurkat Human Cell Line.
Bad was detected in immersion fixed Jurkat human acute T cell leukemia cell line using Rabbit Anti-Human/Mouse Bad Antigen Affinity-purified Polyclonal Antibody (Catalog # AF819) at 0.3 µg/mL for 3 hours at room temperature. Cells were stained using the NorthernLights™ 557-conjugated Anti-Rabbit IgG Secondary Antibody (red; Catalog # NL004) and counterstained with DAPI (blue). Specific staining was localized to cytoplasm. View our protocol for Fluorescent ICC Staining of Non-adherent Cells.Applications for Human/Mouse Bad aa 1‑21 Antibody
Application
Recommended Usage
Immunocytochemistry
0.3-15 µg/mL
Sample: Immersion fixed Jurkat human acute T cell leukemia cell line
Sample: Immersion fixed Jurkat human acute T cell leukemia cell line
Western Blot
1 µg/mL
Sample: A431 human epithelial carcinoma cell line, Jurkat human acute T cell leukemia cell line, HepG2 human hepatocellular carcinoma cell line, and L‑929 mouse fibroblast cell line
Sample: A431 human epithelial carcinoma cell line, Jurkat human acute T cell leukemia cell line, HepG2 human hepatocellular carcinoma cell line, and L‑929 mouse fibroblast cell line
Reviewed Applications
Read 2 reviews rated 4 using AF819 in the following applications:
Formulation, Preparation, and Storage
Purification
Antigen Affinity-purified
Reconstitution
Reconstitute at 0.2 mg/mL in sterile PBS. For liquid material, refer to CoA for concentration.
Loading...
Formulation
Lyophilized from a 0.2 μm filtered solution in PBS with Trehalose. *Small pack size (SP) is supplied either lyophilized or as a 0.2 µm filtered solution in PBS.
Shipping
Lyophilized product is shipped at ambient temperature. Liquid small pack size (-SP) is shipped with polar packs. Upon receipt, store immediately at the temperature recommended below.
Stability & Storage
Use a manual defrost freezer and avoid repeated freeze-thaw cycles.
- 12 months from date of receipt, -20 to -70 °C as supplied.
- 1 month, 2 to 8 °C under sterile conditions after reconstitution.
- 6 months, -20 to -70 °C under sterile conditions after reconstitution.
Calculators
Background: Bad
Long Name
Bcl-xL/Bcl-2 Associated Death Promoter
Alternate Names
BBC6, BCL2L8
Gene Symbol
BAD
UniProt
Additional Bad Products
Product Documents for Human/Mouse Bad aa 1‑21 Antibody
Certificate of Analysis
To download a Certificate of Analysis, please enter a lot or batch number in the search box below.
Note: Certificate of Analysis not available for kit components.
Product Specific Notices for Human/Mouse Bad aa 1‑21 Antibody
For research use only
Related Research Areas
Citations for Human/Mouse Bad aa 1‑21 Antibody
Customer Reviews for Human/Mouse Bad aa 1‑21 Antibody (2)
4 out of 5
2 Customer Ratings
Have you used Human/Mouse Bad aa 1‑21 Antibody?
Submit a review and receive an Amazon gift card!
$25/€18/£15/$25CAN/¥2500 Yen for a review with an image
$10/€7/£6/$10CAN/¥1110 Yen for a review without an image
Submit a review
Customer Images
Showing
1
-
2 of
2 reviews
Showing All
Filter By:
-
Application: MicroarraySample Tested: EDTA PlasmaSpecies: HumanVerified Customer | Posted 12/07/2020Antibody was printed on custom arrays and incubated with fluorescently labeled human EDTA plasma
-
Application: Western BlotSample Tested: Lung tissue and Lung single-cell suspensionSpecies: MouseVerified Customer | Posted 06/05/2019
There are no reviews that match your criteria.
Protocols
Find general support by application which include: protocols, troubleshooting, illustrated assays, videos and webinars.
- Appropriate Fixation of IHC/ICC Samples
- Cellular Response to Hypoxia Protocols
- ClariTSA™ Fluorophore Kits
- Detection & Visualization of Antibody Binding
- ICC Cell Smear Protocol for Suspension Cells
- ICC Immunocytochemistry Protocol Videos
- ICC for Adherent Cells
- Immunocytochemistry (ICC) Protocol
- Immunocytochemistry Troubleshooting
- Immunofluorescence of Organoids Embedded in Cultrex Basement Membrane Extract
- Immunohistochemistry (IHC) and Immunocytochemistry (ICC) Protocols
- Preparing Samples for IHC/ICC Experiments
- Preventing Non-Specific Staining (Non-Specific Binding)
- Primary Antibody Selection & Optimization
- Protocol for VisUCyte™ HRP Polymer Detection Reagent
- Protocol for the Fluorescent ICC Staining of Cell Smears - Graphic
- Protocol for the Fluorescent ICC Staining of Cultured Cells on Coverslips - Graphic
- Protocol for the Preparation and Fluorescent ICC Staining of Cells on Coverslips
- Protocol for the Preparation and Fluorescent ICC Staining of Non-adherent Cells
- Protocol for the Preparation and Fluorescent ICC Staining of Stem Cells on Coverslips
- Protocol for the Preparation of a Cell Smear for Non-adherent Cell ICC - Graphic
- R&D Systems Quality Control Western Blot Protocol
- TUNEL and Active Caspase-3 Detection by IHC/ICC Protocol
- The Importance of IHC/ICC Controls
- Troubleshooting Guide: Western Blot Figures
- Western Blot Conditions
- Western Blot Protocol
- Western Blot Protocol for Cell Lysates
- Western Blot Troubleshooting
- Western Blot Troubleshooting Guide
- View all Protocols, Troubleshooting, Illustrated assays and Webinars
Loading...
Associated Pathways
IL-7 Signaling Pathways
IL-9 Signaling Pathways
IL-15 Signaling Pathways
IL-21 Signaling Pathways
MAPK Signaling: Oxidative Stress Pathway
VEGF - VEGF R2 Signaling Pathways